Image-Based Mechanical Analysis of Stent Deformation: Concept and Exemplary Implementation for Aortic Valve Stents
Open Access
- 16 July 2013
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 61 (1) , 4-15
Abstract
An approach for extracting the radial force load on an implanted stent from medical images is proposed. To exemplify the approach, a system is presented which computes a radial force estimation from computer tomography images acquired from patients who underwent transcatheter aortic valve implantation (TAVI). The deformed shape of the implanted valve prosthesis' Nitinol frame is extracted from the images. A set of displacement vectors is computed that parameterizes the observed deformation. An iterative relaxation algorithm is employed to adapt the information extracted from the images to a finite-element model of the stent, and the radial components of the interaction forces between the stent and the tissue are extracted. For the evaluation of the method, tests were run using the clinical data from 21 patients. Stent modeling and extraction of the radial forces were successful in 18 cases. Synthetic test cases were generated, in addition, for assessing the sensitivity to the measurement errors. In a sensitivity analysis, the geometric error of the stent reconstruction was below 0.3 mm, which is below the image resolution. The distribution of the radial forces was qualitatively and quantitatively reasonable. An uncertainty remains in the quantitative evaluation of the radial forces due to the uncertainty in defining a radial direction on the deformed stent. With our approach, the mechanical situation of TAVI stents after the implantation can be studied in vivo, which may help to understand the mechanisms that lead to the complications and improve stent design.Keywords
This publication has 20 references indexed in Scilit:
- Quantification of Biomechanical Interaction of Transcatheter Aortic Valve Stent Deployed in Porcine and Ovine HeartsAnnals of Biomedical Engineering, 2012
- A multi-scale mechanobiological model of in-stent restenosis: deciphering the role of matrix metalloproteinase and extracellular matrix changesComputer Methods in Biomechanics and Biomedical Engineering, 2012
- Numerical analysis of the radial force produced by the Medtronic-CoreValve and Edwards-SAPIEN after transcatheter aortic valve implantation (TAVI)Medical Engineering & Physics, 2012
- Computed tomography-based evaluation of aortic annulus, prosthesis size and impact on early residual aortic regurgitation after transcatheter aortic valve implantationEuropean Journal of Cardio-Thoracic Surgery, 2012
- Cubic hermite bezier spline based reconstruction of implanted aortic valve stents from CT images2011
- In-vivo Imaging of Femoral Artery Nitinol Stents for Deformation AnalysisJournal of Vascular and Interventional Radiology, 2011
- Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo SurgeryNew England Journal of Medicine, 2010
- Comparison of Element Technologies for Modeling Stent ExpansionJournal of Biomechanical Engineering, 2006
- First report on a human percutaneous transluminal implantation of a self-expanding valve prosthesis for interventional treatment of aortic valve stenosisCatheterization and Cardiovascular Interventions, 2005
- Evaluation of the risks of using an oversized balloon catheter in the human infrarenal abdominal aortaEuropean Journal of Vascular and Endovascular Surgery, 1998