Diagnostic Accuracy of Radiomics Versus Visual or Threshold-Based Assessment for Myocardial Scar/Fibrosis Detection on Cardiac MRI: A Systematic Review
Open Access
Abstract
Background: Myocardial scar and fibrosis predict adverse cardiac outcomes. Late gadolinium enhancement (LGE) cardiac magnetic resonance (CMR) is the reference standard for detection. However, it requires gadolinium-based contrast agents (GBCAs), which may be unsuitable for some patients. Cine balanced steady-state free precession (bSSFP) sequences are universally acquired in routine CMR. They may enable contrast-free scar detection via radiomics analysis. Aim: To systematically review the diagnostic accuracy of cine CMR radiomics for myocardial scar or fibrosis detection. The reference standard is visual or threshold-based LGE. Methods: This review followed PRISMA guidelines and was registered in PROSPERO (CRD420251121699). We searched MEDLINE, Embase, and Cochrane Library up to 8 August 2025. Eligible studies compared cine CMR radiomics with LGE-based assessment in patients with suspected or known scar/fibrosis. Quality was assessed using QUADAS-2 and Radiomics Quality Score (RQS). Results: Five retrospective studies (n = 1484) were included. Two focused on myocardial infarction, two on hypertrophic cardiomyopathy, and one on ischaemic versus dilated cardiomyopathy. Diagnostic performance was good to excellent (AUC 0.74–0.96). Methodological heterogeneity was substantial in reference standards, segmentation, preprocessing, feature selection, and modelling. Only one study used external validation. QUADAS-2 showed high bias risk in patient selection and index test domains. RQS scores were low (30–42%), indicating limited reproducibility and validation. Conclusions: Cine CMR radiomics shows promise as a non-contrast alternative for detecting myocardial scar and fibrosis. However, methodological standardisation, multicentre validation, and prospective studies are needed before clinical adoption.Keywords
All Related Versions
This publication has 26 references indexed in Scilit:
- Radiomics for differential diagnosis of ischemic and dilated cardiomyopathy using non-contrast-enhanced cine cardiac magnetic resonance imagingLa radiologia medica, 2025
- MRI Gadolinium‐Based Contrast Media: Meeting Radiological, Clinical, and Environmental NeedsJournal of Magnetic Resonance Imaging, 2024
- Bringing MRI to low‐ and middle‐income countries: Directions, challenges and potential solutionsNMR in Biomedicine, 2023
- Cardiac magnetic resonance radiomics for disease classificationEuropean Radiology, 2022
- Identification of fibrosis in hypertrophic cardiomyopathy: a radiomic study on cardiac magnetic resonance cine imagingEuropean Radiology, 2022
- 2022 AHA/ACC/HFSA Guideline for the Management of Heart FailureJACC, 2022
- Non-contrast Cine Cardiac Magnetic Resonance image radiomics features and machine learning algorithms for myocardial infarction detectionComputers in Biology and Medicine, 2022
- Myocardial fibrosis: morphologic patterns and role of imaging in diagnosis and prognosticationCardiovascular Pathology, 2022
- Multimodality Imaging Assessment of Myocardial FibrosisJACC: Cardiovascular Imaging, 2021
- Myocardial Tissue Characterization and Fibrosis by ImagingJACC: Cardiovascular Imaging, 2020