Air-Gap Power-Based Sensorless Control in a DFIG Connected to a DC Link
Authors:
- 8 October 2014
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 30 (1) , 367-375
Abstract
This paper deals with the sensorless vector control of a doubly fed induction generator (DFIG) whose stator is connected by a rectifier to a dc link, which also feeds the rotor-side inverter. A noticeable reduction of the costs can be achieved by this topology, because only a single inverter and a diode rectifier are needed instead of the traditional back-to-back converter. A sensorless stator-flux-oriented control is implemented by using an observer, which directly computes the necessary slip angle based on of the air-gap power and without the need of the stator flux estimation. The direct-axis component of the rotor current is adjusted to regulate the stator frequency near the rated value. In order to track the actual stator frequency, the phase-locked-loop approach is used. The control method is validated by simulations and experimental results obtained using a small-rating laboratory setup.Keywords
Funding Information
- Fundação para a Ciência e a Tecnologia (FCT) (Pest-OE/EEI/LA0021/2013)
This publication has 33 references indexed in Scilit:
- Stator Frequency Regulation in a Field-Oriented Controlled DFIG Connected to a DC LinkIEEE Transactions on Industrial Electronics, 2014
- Sensorless torque control of a DFIG connected to a DC link2013
- Stator Inductance Self-Tuning in an Air-Gap-Power-Vector-Based Observer for the Sensorless Control of Doubly Fed Induction MachinesIEEE Transactions on Industrial Electronics, 2013
- Design-Oriented Study of Advanced Synchronous Reference Frame Phase-Locked LoopsIEEE Transactions on Power Electronics, 2013
- A Novel Distributed Direct-Voltage Control Strategy for Grid Integration of Offshore Wind Energy Systems Through MTDC NetworkIEEE Transactions on Industrial Electronics, 2012
- Understanding the Doubly Fed Induction Generator During Voltage DipsIEEE Transactions on Energy Conversion, 2012
- A Study of Efficiency in a Reduced Matrix Converter for Offshore Wind FarmsIEEE Transactions on Industrial Electronics, 2011
- Dynamic Modeling and Improved Control of DFIG Under Distorted Grid Voltage ConditionsIEEE Transactions on Energy Conversion, 2010
- Continuous conduction mode operation of three-phase diode bridge rectifier with constant load voltageIEE Proceedings - Electric Power Applications, 2005
- Performance Improvement of Alternators With Switched-Mode RectifiersIEEE Transactions on Energy Conversion, 2004