Comparison of two dust collection methods for reservoir indoor allergens and endotoxin on carpets and mattresses
- 1 June 2004
- journal article
- research article
- Published by Hindawi Limited in Indoor Air
- Vol. 14 (3) , 217-222
Abstract
Variable methods of dust collection may lead to uncertainty in the measurement of biomarkers. The purpose of this study was to examine the effect of two different dust collection devices on dust weight, Der p 1, Fel d 1, and endotoxin levels. We compared: (1) a nylon mesh sock inserted between the furniture attachment and the vacuum hose (the reference method) and (2) the ALK device. Duplicate dust samples were collected for 2 min from 2 m(2) of 37 living room floors and from each longitudinal half of 37 mattresses. Measurement of Der p 1 and Fel d 1 were by double monoclonal antibody enzyme-linked immunosorbent assay (ELISA) and endotoxin by a Limulus Amobocyte Lysate assay. Geometric mean ratios (95% confidence intervals) were calculated to show the differences between sampling devices for each measurement. Compared with the ALK device, the reference method collected significantly more dust from floors (sevenfold) and mattresses (threefold) and more total Der p 1, Fel d 1, and endotoxin in both sites. Floor, but not mattress, Der p 1 concentrations were also significantly higher (threefold) using our reference method. We recommend that, in order to minimize sampling device bias, allergen and endotoxin are expressed as a concentration, and that the bed is considered the major source of allergen exposure. Practical Implications Dust sampling equipment can influence the dust yield. In order to have confidence in comparisons of allergen and endotoxin reservoir levels between centers, standardization in the use of sampling equipment is important.Keywords
This publication has 18 references indexed in Scilit:
- Quantitative measurement of airborne allergens from dust mites, dogs, and cats using an ion‐charging deviceClinical & Experimental Allergy, 2003
- Respiratory symptoms in relation to indoor exposure to mite and cat allergens and endotoxinsEuropean Respiratory Journal, 2001
- A Comparison of the Sampling Characteristics of Two Vacuum Surface Samplers for the Collection of Dust Mite AllergenApplied Occupational and Environmental Hygiene, 1998
- Exposure to house dust mite allergens and the clinical activity of asthmaJournal of Allergy and Clinical Immunology, 1996
- Variability and repeatability of house dust mite allergen measurement: implications for study design and interpretationClinical & Experimental Allergy, 1995
- Mite antigen in house dust: relationship with different housing characteristics in the NetherlandsClinical & Experimental Allergy, 1994
- The effect of vacuum cleaners on the concentration and particle size distribution of airborne cat allergenJournal of Allergy and Clinical Immunology, 1993
- Dust mite allergens and asthma: Report of a second international workshopJournal of Allergy and Clinical Immunology, 1992
- Airborne dust mite allergens: Comparison of group II allergens with group I mite allergen and cat-allergen Fel d IJournal of Allergy and Clinical Immunology, 1991
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986