Interplay Among Muscle Oxygen Saturation, Activation, and Power on a Swim-Bench
Open Access
Abstract
Muscle activity during exercise is typically assessed using oximeters, to evaluate local oxygen saturation (SmO2), or surface electromyography (sEMG), to analyze electrical activation. Despite the importance of combining these analyses, no study has evaluated both of them during specific swimming exercises in combination with mechanical power output. This study aimed to assess muscle activity during an incremental test on a swim-bench utilizing oximeters and sEMG. Nine male swimmers performed a five-steps test: PRE (3 min at rest), STEP 1, 2, and 3 (swimming at a frequency of 25, 30, and 40 cycle/min for a duration of 2, 2, and 1 min, respectively), and POST (5 min at rest). Each swimmer wore two oximeters and sEMG, one for each triceps brachii. Stroke frequency and arm mechanical power (from ~13 to ~52 watts) estimated by the swim-bench were different among all steps, while no differences between arms were found. SmO2 (from ~70% to ~60%) and sEMG signals (from ~20 to ~65% in signal amplitude) showed a significant increase among all steps. In both arms, a large/very large correlation was found between mechanical power and SmO2 (r < −0.634), mechanical power and sEMG onset/amplitude (r > 0.581), and SmO2 and sEMG amplitude (r > 0.508). No correlations were found between the slope of the sEMG spectral indexes and the slope of SmO2; only sEMG detected electrical manifestation of muscle fatigue through the steps (p < 0.05). Increased muscle activity, assessed by both oximeters and sEMG, was found at mechanical power increases, revealing both devices can detect effort variation during exercise. However, only sEMG seems to detect peripheral manifestations of fatigue in dynamic conditions.Keywords
This publication has 61 references indexed in Scilit:
- Muscle Oximetry in Sports Science: An Updated Systematic ReviewSports Medicine, 2024
- A systematic review on fatigue analysis in triceps brachii using surface electromyographyBiomedical Signal Processing and Control, 2018
- Muscle Oximetry in Sports Science: A Systematic ReviewSports Medicine, 2017
- Comparison of two devices using near-infrared spectroscopy for the measurement of tissue oxygenation during a vascular occlusion test in healthy volunteers (INVOS® vs. InSpectra™)Journal of Clinical Monitoring and Computing, 2014
- Dynamic evaluation of near-infrared peripheral oximetry in healthy volunteers: A comparison between INVOS and EQUANOXJournal of Critical Care, 2013
- Detection of changes in muscle oxygen saturation in the human leg: a comparison of two near-infrared spectroscopy devicesJournal of Clinical Monitoring and Computing, 2013
- Evaluation of muscle fatigue during 100-m front crawlEuropean Journal of Applied Physiology, 2010
- Biceps brachii myoelectric and oxygenation changes during static and sinusoidal isometric exercisesJournal of Electromyography and Kinesiology, 2009
- Reliability of Near-Infrared Spectroscopy in People With Dark Skin PigmentationJournal of Clinical Monitoring and Computing, 2005
- Assessment of lower-back muscle fatigue using electromyography, mechanomyography, and near-infrared spectroscopyEuropean Journal of Applied Physiology, 2001