Noninvasive Intraocular Pressure Measurements in Mice by Pneumotonometry
- 1 September 2005
- journal article
- research article
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 46 (9) , 3274-3280
Abstract
Purpose. To develop a reliable, noninvasive, continuous, and easily implemented system for measuring intraocular pressure (IOP) in mice. methods. Pneumotonometry was adapted for measurement of mouse IOP. Measurements were compared with those obtained with the servo-null micropipette system (SNMS) and with direct anterior chamber cannulation. Heart rate was monitored by the precordial pulse, EKG, or tail pulse in anesthetized mice. The characteristic ocular hypotensive response to mannitol was assessed as an additional validation of the method. results. Measurements of IOP obtained using pneumotonometry agreed closely with values measured by SNMS or by direct cannulation. IOP oscillations were synchronous with the heart rate, with a coherence peak between them of ∼2 Hz, equal to the pulse frequency. Hypertonic mannitol reduced IOP from 13.7 ± 0.9 mm Hg by 7.7 ± 0.7 mm Hg after 15 minutes. conclusions. Pneumotonometry is a reliable and noninvasive method for the measurement of IOP in mice and may permit comparisons of IOP to hemodynamic factors. This system is simpler and more adaptable for glaucoma research than previously reported methodologies for measuring IOP in mice.Keywords
This publication has 23 references indexed in Scilit:
- On the use of Tono-Pen XL for the measurement of intraocular pressure in miceExperimental Eye Research, 2005
- Tonopen measurement of intraocular pressure in miceExperimental Eye Research, 2004
- A sleep apnea syndrome detection system.2004
- Twenty-four-hour pattern of mouse intraocular pressureExperimental Eye Research, 2003
- Episcleral venous pressure of mouse eye and effect of body positionCurrent Eye Research, 2003
- A1‐, A2A‐ and A3‐subtype adenosine receptors modulate intraocular pressure in the mouseBritish Journal of Pharmacology, 2001
- The advanced glaucoma intervention study (AGIS): 7. the relationship between control of intraocular pressure and visual field deteriorationAmerican Journal of Ophthalmology, 2000
- The effectiveness of intraocular pressure reduction in the treatment of normal-tension glaucomaAmerican Journal of Ophthalmology, 1998
- The advanced glaucoma intervention study (AGIS): 4. comparison of treatment outcomes within raceOphthalmology, 1998
- The Ocular Blood Flow Tonograph: A New Instrument for the Measurement of Intraocular Pressure in RabbitsExperimental Eye Research, 1996