OBJECTIVE: The goal of this study was to determine the performance of intraoperative visual evoked potentials (VEPs) in detecting visual field changes. METHODS: Assessments of VEPs were performed with simultaneous retinal responses by using white light-emitting diodes protected from scialytic microscope lights. The alarm criterion was a reproducible decrease in amplitude of the VEP P100 wave of 20% or more. Visual fields were assessed preoperatively and 1 month postsurgery (Goldmann perimetry). RESULTS: The VEPs were analyzed for 29 patients undergoing resection of a brain lesion. In 89.7% of patients, steady VEP and retinal responses were obtained for monitoring. The absence of alarm was associated in 94.4% of cases with the absence of postoperative visual changes (specificity). The alarms correctly identified 66.7% of cases with any postoperative changes and 100% of cases with changes more severe than just a discrete quadrantanopia or deterioration of an existing quadrantanopia (sensitivity, new diffuse deterioration < 2 dB). In 11.5% of patients, a transitory VEP decrease with subsequent recovery was observed without postoperative defects. CONCLUSIONS: Intraoperative VEPs were performed with simultaneous recording of electroretinograms, with protection from lights of the operating room and with white light-emitting diodes. Intraoperative VEPs were shown to be reliable in predicting postoperative visual field changes. In this series of intraaxial brain procedures, reliable intraoperative VEP monitoring was achieved, allowing at minimum the detection of new quadrantanopia. The standardization of this technique appears to be a valuable effort in regard to the functional risks of homonymous hemianopia.Keywords
This publication has 19 references indexed in Scilit:
- 'Hemispherical asymmetry in the Meyer's Loop': a prospective study of visual-field deficits in 105 cases undergoing anterior temporal lobe resection for epilepsyJournal of Neurology, Neurosurgery & Psychiatry, 2010
- Standard and limitation of intraoperative monitoring of the visual evoked potentialActa Neurochirurgica, 2010
- Intraoperative monitoring of visual evoked potential: introduction of a clinically useful methodJournal of Neurosurgery, 2010
- Defining Meyer's loop-temporal lobe resections, visual field deficits and diffusion tensor tractographyBrain, 2009
- Prediction of visual field deficits by diffusion tensor imaging in temporal lobe epilepsy surgeryNeuroImage, 2009
- VISUAL FIELD DEFECTS IN SELECTIVE AMYGDALOHIPPOCAMPECTOMY FOR HIPPOCAMPAL SCLEROSISNeurosurgery, 2008
- Motor tract monitoring during insular glioma surgeryJournal of Neurosurgery, 2007
- Monitoring of intraoperative motor evoked potentials to increase the safety of surgery in and around the motor cortexJournal of Neurosurgery, 2001
- Transcranial Electrical Motor Evoked Potential Monitoring for Brain Tumor ResectionNeurosurgery, 2001
- Monitoring optic nerve function during craniotomyJournal of Neurosurgery, 1976