Simultaneous analysis of Cr and Pb in contaminated pork by laser-induced breakdown spectroscopy
Authors:
- 5 October 2017
- journal article
- Published by Optica Publishing Group in Applied Optics
- Vol. 56 (29) , 8148-8153
Abstract
Laser-induced breakdown spectroscopy (LIBS) as a rapid and green method was used to detect heavy metals Cr and Pb in pork contaminated in the lab. The laser-induced plasma was generated by a -switched Nd:YAG laser, and the LIBS signal was collected by a spectrometer with a charge-coupled device detector. The traditional calibration curves (CC) and multivariate partial least squares (PLS) algorithm were applied and compared to validate the accuracy in predicting the content of heavy metals in samples. The results demonstrated that the correlation coefficient of CC is poor by the classical univariate calibration method, so the univariate calibration analysis cannot effectively serve the quantitative purpose in analyzing heavy metals’ residue in pork with a complex matrix. The analysis accuracy was improved effectively by the PLS method, and the correlation coefficient is 0.9894 for Cr and 0.9908 for Pb. The concentration of Cr and Pb in samples from a prediction set was obtained using the PLS calibration method, and the average relative errors for the 21 samples in the prediction set are lower than 6.53% and 7.82% for Cr and Pb, respectively. The investigated results display that the matrix effect would be reduced effectively during the quantitative analysis of pork by a LIBS-combined PLS model, and the predictive accuracy would be improved greatly compared to traditional univariate analysis.
Keywords
Funding Information
- National Natural Science Foundation of China (NSFC) (31460419, 31560482)
- Jiangxi Key Technology R&D Program (20151BBG70063)
- Major Project of Science and Technology of Jiangxi (20143ACB21013)
- Jiangxi Sailing Project 2014
This publication has 20 references indexed in Scilit:
- Good practices in LIBS analysis: Review and advicesSpectrochimica Acta Part B: Atomic Spectroscopy, 2014
- A model combining spectrum standardization and dominant factor based partial least square method for carbon analysis in coal using laser-induced breakdown spectroscopySpectrochimica Acta Part B: Atomic Spectroscopy, 2014
- Trace elemental analysis by laser-induced breakdown spectroscopy—Biological applicationsSurface Science Reports, 2012
- Laser-induced breakdown spectroscopy for analysis of plant materials: A reviewSpectrochimica Acta Part B: Atomic Spectroscopy, 2012
- Laser-induced breakdown spectroscopy (LIBS): an overview of recent progress and future potential for biomedical applicationsJournal of Medical Engineering & Technology, 2012
- A non-linearized PLS model based on multivariate dominant factor for laser-induced breakdown spectroscopy measurementsJournal of Analytical Atomic Spectrometry, 2011
- Copper content in animal manures and potential risk of soil copper pollution with animal manure use in agricultureResources, Conservation and Recycling, 2010
- Copper, zinc and manganese in soils of two watersheds in Santa Catarina with intensive use of pig slurryRevista Brasileira de Ciência do Solo, 2010
- Multi-element analysis of iron ore pellets by Laser-induced Breakdown Spectroscopy and Principal Components RegressionSpectrochimica Acta Part B: Atomic Spectroscopy, 2008
- Multi-elemental analysis of solidified mineral melt samples by Laser-Induced Breakdown Spectroscopy coupled with a linear multivariate calibrationSpectrochimica Acta Part B: Atomic Spectroscopy, 2007