Ozone generation in oxygen by corona discharges in a point-to-plane gap subjected to a chopped DC positive voltage
Authors:
- 14 December 1981
- journal article
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 14 (12) , 2237-2242
Abstract
It is shown that the ozone generation increases when a chopped DC positive voltage, frequency 2.5 kHz, is applied to a point-to-plane gap, compared with production obtained with a DC negative voltage. This method makes it possible to limit the thermal destruction effect and leads to a better repartition into the volume of the production by electron impact and photoionisation. It is thus possible to reach a concentration of 600 PPM with a yield of 125 PPM W-1 h-1.Keywords
This publication has 6 references indexed in Scilit:
- The formation of small sparksJournal of Applied Physics, 1977
- Lifetime of1Σg+oxygen state produced in a corona dischargeJournal of Physics B: Atomic and Molecular Physics, 1975
- Increased efficiency of ozone-production by electric dischargesElectrochimica Acta, 1973
- Gas Heating Effects in the Constriction of a High-Pressure Glow Discharge ColumnThe Physics of Fluids, 1972
- Chemical Reaction in Silent Electric Discharge. I. The Mechanism of Ozone FormationBulletin of the Chemical Society of Japan, 1970
- The Mechanism of Ozone Formation in Electrical Discharges1959