Square-Wave Anodic Stripping Voltammetry (SWASV) for the Determination of Ecotoxic Metals, Using a Bismuth-Film Electrode
Authors:
- 15 March 2011
- journal article
- research article
- Published by Taylor & Francis in Analytical Letters
- Vol. 44 (5) , 761-777
Abstract
This article reviews the use of square wave anodic stripping voltammetry for the simultaneous determination of ecotoxic metals (Pb, Cd, Cu, and Zn) on a bismuth-film (BiFE) electrode. The BiFE was prepared in situ on a glassy-carbon electrode (GCE) from the 0.1 mol L−1 acetate buffer solution (pH 4.5) containing 200 µg L−1 of bismuth (III). The addition of hydrogen peroxide to the electroanalytical cell proved beneficial for the interference-free determination of Cu (II) together with zinc, lead, and cadmium, using the BiFE. The experimental variables were investigated and optimized with the view to apply this type of voltammetric sensor to real samples containing traces of these metals. The performance characteristics, such as reproducibility, decision limit (CCa), detection capability (CCβ), sensitivity, and accuracy indicated that the method holds promise for trace Cu2+, Pb2+, Cd2+, and Zn2+ levels by employment of Hg-free GCE with SWASV. CCa, and CCβ were calculated according to the Commission Decision of 12 August 2002 (2002/657/EC). Linearity was observed in the range 20–280 µg L−1 for zinc, 10–100 µg L−1 for lead, 10–80 µg L−1 for copper, and 5–50 µg L−1 for cadmium. Using the optimized conditions, the stripping performance of the BiFE was characterized by low limits of detection (LOD). Finally, the method was successfully applied in real as well as in certified reference water samples.Keywords
This publication has 36 references indexed in Scilit:
- A Novel Cell Design for the Improved Stripping Voltammetric Detection of Zn(II), Cd(II), and Pb(II) on Commercial Screen‐Printed Strips by Bismuth Codeposition in Stirred SolutionsElectroanalysis, 2008
- Use of hydrogen peroxide to achieve interference-free stripping voltammetric determination of copper at the bismuth-film electrodeAnalytica Chimica Acta, 2008
- Lithographically fabricated disposable bismuth-film electrodes for the trace determination of Pb(II) and Cd(II) by anodic stripping voltammetryElectrochimica Acta, 2008
- Utilising gallium for enhanced electrochemical copper analysis at the bismuth film electrodeAnalytica Chimica Acta, 2007
- A study on the utility of bismuth-film electrodes for the determination of In(III) in the presence of Pb(II) and Cd(II) by square wave anodic stripping voltammetryAnalytica Chimica Acta, 2005
- Characterization and Application of Bismuth‐Film Modified Carbon Film ElectrodesElectroanalysis, 2005
- A study of pencil-lead bismuth-film electrodes for the determination of trace metals by anodic stripping voltammetryAnalytica Chimica Acta, 2004
- Determination of heavy metals in wines by anodic stripping voltammetry with thick-film modified electrodeAnalytica Chimica Acta, 2004
- Insights into the anodic stripping voltammetric behavior of bismuth film electrodesAnalytica Chimica Acta, 2001
- Stripping voltammetry for the determination of trace metal speciation and in-situ measurements of trace metal distributions in marine watersAnalytica Chimica Acta, 1999