Effect of cementing technique on aseptic stem loosening in cemented primary total hip arthroplasty: a systematic review and meta-analysis
Authors:
- Muhammad Mbbs HanifMHMuhammad Mbbs Hanif
- Naveed Mbbs ArshadNANaveed Mbbs Arshad
- Yasir Mbbs HabibYHYasir Mbbs Habib
- Ali Miraj Mbbs ShamiASAli Miraj Mbbs Shami
- Obaid Ur Mbbs RehmanORObaid Ur Mbbs Rehman
- Muhammad Mbbs RehmanMRMuhammad Mbbs Rehman
- Muddasir Mbbs ReyazMRMuddasir Mbbs Reyaz
- Hassan Mbbs MumtazHMHassan Mbbs Mumtaz
Open Access
- 16 April 2023
- journal article
- review article
- Published by Wolters Kluwer Health in Annals of Medicine & Surgery
- Vol. 85 (6) , 2884-2895
Abstract
Background and objective: Aseptic stem loosening after total hip arthroplasty surgery is the commonest complication, whether stem is cemented or uncemented. The aseptic cemented stem loosening has been a challenging problem over the years and a leading cause for revision since the inception of total hip arthroplasty. The objective of systematic review and meta-analysis was to determine the impact of cementing technique on aseptic stem loosening in total hip arthroplasty. Methods: Cochrane, CINAHL, Embase, Google scholar, Medline, PubMed were searched in 13 December 2020. Two independent investigators extracted the data and a third investigator’s involvement was reached on consensus. A total of 37 studies of revision rate due to aseptic loosening were reviewed by using fixed/random effects size and were grouped by cementing technique and studies’ characteristics. The data were analyzed through Meta-Essentials and RStudio. Results: In revision total hip arthroplasty, retained femoral components revisions rate due to aseptic loosening were recorded in 37 studies involving 6167 cases. Aseptic loosening rate collectively was 5.8% (CI 95%, 0.03–0.08) and mean follow-up of study was 12.5 years. The average follow-up period, mean age at index revision surgery and percentage of aseptic loosening were insignificantly associated with revision rate (P≥0.05), in meta-regression univariant analyses. Conclusion: This investigative analysis showed that there is a minimal difference between results of cementing techniques of total hip arthroplasty in femoral components in long-term follow-ups, and usually have a low risk of failure.Keywords
This publication has 37 references indexed in Scilit:
- The Basis CL Cemented Femoral Stem: Results after 8.9 Years Follow-upHIP International, 2013
- Long-term results of cemented total hip arthroplasty in patients younger than 30 years and the outcome of subsequent revisionsBMC Musculoskeletal Disorders, 2013
- Critical factors in cut-out complication after gamma nail treatment of proximal femoral fracturesBMC Musculoskeletal Disorders, 2013
- Factors affecting aseptic loosening of 4750 total hip arthroplasties: multivariate survival analysisBMC Musculoskeletal Disorders, 2007
- Mid-Term Results of Exeter vs Endurance Cemented StemsThe Journal of Arthroplasty, 2006
- Aseptic looseningGene Therapy, 2004
- Total hip replacement with second generation cementing technique and the monobloc ScanHip: a 10-year follow-upInternational Orthopaedics, 2002
- Hip Arthroplasty with a collared straight cobalt-chrome femoral stem using second-generation cementing techniqueThe Journal of Arthroplasty, 2000
- Aseptic loosening of Boneloc R cemented hip prosthesesInternational Orthopaedics, 1997
- Clinical and radiographic analysis of the uncemented lsf total hip arthroplastyThe Journal of Arthroplasty, 1992