Fixation Release and the Bone Bandaid: A New Bone Fixation Device Paradigm
Open Access
- 22 January 2017
- journal article
- research article
- Published by MDPI AG in Bioengineering
- Vol. 4 (1) , 5
Abstract
The current gold standard of care for mandibular segmental defeat reconstruction is the use of Ti-6Al-4V immobilization hardware and fibular double barrel graft. This method is often successful immediately at restoring mandible function, however the highly stiff fixation hardware causes stress shielding of the grafted bone and stress concentration in the fixation device over time which can lead to fixation device failure and revision surgery. The purpose of reconstructive surgery could be to create normal stress trajectories in the mandible following engraftment. We investigate the use of a two stage mechanism which separates the immobilization/healing and regenerative phases of mandibular segmental defect treatment. The device includes the use of a very stiff, Ti-6Al-4V, releasable mechanism which assures bone healing. Therefore it could be released once the reconstructed boney tissue and any of its ligamentous attachments have completely healed. Underneath the released Ti-6Al-4V plate would be a pre-loaded nitinol (NiTi) wire-frame apparatus that facilitates the normal stress-strain trajectory through the engrafted bone after the graft is healed in place and the Ti-6Al-4V fixation device has been released. Due to the use of NiTi wires forming a netting that connects vascularized bone and possibly bone chips, bone grafts are also more likely to be incorporate rather than to resorb. We first evaluated a healthy adult mandible during normal mastication to obtain the normal stress-strain distribution. Then, we developed the finite element (FE) model of the mandibular reconstruction (in the M1-3 region) with the proposed fixation device during the healing (locked state) and post-healing (released state) periods. To recreate normal stress trajectory in the reconstructed mandible, we applied the Response Surface Methodology (RMS) to optimize the Bone Bandaid geometry (i.e., wire diameters and location). The results demonstrate that the proposed mechanism immobilizes the grafted bone in the locked state properly since the maximum resultant gap (21.54 micron) between the graft and host mandible surfaces are in the safe region (less than 300 micron). By considering the von Mises criteria for failure, FE analysis together with experimental studies (i.e., compressive and tensile testing on the inferior and superior fixation devices, respectively) confirm that the proposed fixation devices do not fail, showing safety factor of at least 10.3. Based on the Response Surface Methodology (RSM) technique, the optimal parameter values for the wires are achieved (0.65 mm and 1 mm for the superior and inferior wires, respectively) and the required level of preload on each wire are calculated (369.8 N and 229 N for the inferior and superior wires, respectively). The FE results for stress distribution on the reconstructed mandible during the released state closely match that of a healthy mandible.Keywords
This publication has 49 references indexed in Scilit:
- A multidisciplinary framework to support the design of injection mold toolsStructural and Multidisciplinary Optimization, 2013
- Thermophoresis effect on volatile particle concentration in micro-organic dust flamePowder Technology, 2012
- Investigation of stress shielding around the Stryker Omnifit and Exeter periprosthetic hip implants using an irreversible thermodynamic‐based modelJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2011
- Torsional Behavior of NiTi Wires and Tubes: Modeling and ExperimentationJournal of Intelligent Material Systems and Structures, 2011
- In situ parameter identification of optimal density–elastic modulus relationships in subject-specific finite element models of the proximal femurMedical Engineering & Physics, 2010
- Photocatalytic degradation of azo dye (Reactive Red 120) in TiO2/UV system: Optimization and modeling using a response surface methodology (RSM) based on the central composite designDyes and Pigments, 2007
- Mandibular Mechanics After Osteotomy and Distraction Appliance Placement I: Postoperative Mobility of the Osteotomy SiteJournal of Oral and Maxillofacial Surgery, 2006
- Mandibular Mechanics Following Osteotomy and Appliance Placement II: Bone Strain on the Body and Condylar NeckJournal of Oral and Maxillofacial Surgery, 2006
- Bite forces in patients treated for mandibular angle fractures: Implications for fixation recommendationsJournal of Oral and Maxillofacial Surgery, 1994
- Three‐dimensional finite element stress analysis of the dentate human mandibleAmerican Journal of Physical Anthropology, 1992