A Novel Impedimetric Microfluidic Analysis System for Transgenic Protein Cry1Ab Detection
Authors:
Open Access
- 2 March 2017
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , srep43175
Abstract
Impedimetric analysis method is an important tool for food safety detection. In this work, a novel impedimetric microfluidic analysis system consisted of a printed gold electrode chip and a microfluidic flow cell was developed for sensitive and selective detection of transgenic protein Cry1Ab. Anti-Cry1Ab aptamer coated magnetic beads were used to recognize transgenic protein Cry1Ab and form Cry1Ab-aptamer modified magnetic beads. After separation, the obtained Cry1Ab-aptamer modified magnetic beads were dissolved in 0.01 M mannitol and followed by injection into the microfluidic flow cell for impedimetric measurement. At the frequency of 358.3 Hz, the impedance signal shows a good linearity with the concentrations of Cry1Ab protein at a range from 0 to 0.2 nM, and the detection limit is 0.015 nM. The results demonstrate that the impedimetric microfluidic analysis system provides an alternative way to enable sensitive, rapid and specific detection of transgenic protein Cry1Ab.Keywords
This publication has 37 references indexed in Scilit:
- An optimised electrochemical biosensor for the label-free detection of C-reactive protein in bloodBiosensors and Bioelectronics, 2013
- A Fast and Sensitive Quantitative Lateral Flow Immunoassay for Cry1Ab Based on a Novel Signal Amplification ConjugateSensors, 2012
- Adsorption of Insecticidal Cry1Ab Protein to Humic Substances. 1. Experimental Approach and Mechanistic AspectsEnvironmental Science & Technology, 2012
- A microfluidic-based frequency-multiplexing impedance sensor (FMIS)Lab on a Chip, 2012
- EIS microfluidic chips for flow immunoassay and ultrasensitive cholera toxin detectionLab on a Chip, 2010
- Adsorption of Transgenic Insecticidal Cry1Ab Protein to SiO2. 1. Forces Driving AdsorptionEnvironmental Science & Technology, 2010
- Development and validation of a sensitive enzyme immunoassay for surveillance of Cry1Ab toxin in bovine blood plasma of cows fed Bt-maize (MON810)Analytica Chimica Acta, 2008
- Label-Free Detection of Bacteria by Electrochemical Impedance Spectroscopy: Comparison to Surface Plasmon ResonanceAnalytical Chemistry, 2007
- Development of ELISA for the Determination of Transgenic Bt‐Cottons Using Antibodies against Cry1Ac Protein from Bacillus thuringiensis HD‐73Engineering in Life Sciences, 2007
- Development of Monoclonal Antibodies Against Cry1Ab Protein fromBacillus thuringiensisand Their Application in an ELISA for Detection of Transgenic Bt-MaizeFood and Agricultural Immunology, 2002