An easy to assemble microfluidic perfusion device with a magnetic clamp
- 6 February 2009
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 9 (8) , 1085-1095
Abstract
We have built and characterized a magnetic clamp for reversible sealing of PDMS microfluidic chips against cover glasses with cell cultures and a microfluidic chip for experiments on shear stress response of endothelial cells. The magnetic clamp exerts a reproducible uniform pressure on the microfluidic chip, achieving fast and reliable sealing for liquid pressures up to 40 kPa inside the chip with 2. Excellent cell viability at all shear stresses and alignment of cells along the flow at high shear stresses are repeatedly observed. A scratch wound healing assay under a shear flow is demonstrated and cell migration velocities are measured. Transfection of cells with a fluorescent protein is performed, and migrating fluorescent cells are imaged at a high resolution under shear flow in real time. The magnetic clamp can be closed with minimal mechanical perturbation to cells on the substrate and used with a variety of microfluidic chips for experiments with adherent and non-adherent cells.Keywords
This publication has 48 references indexed in Scilit:
- Interactions between Multiple Cell Types in Parallel Microfluidic Channels: Monitoring Platelet Adhesion to an Endothelium in the Presence of an Anti-Adhesion DrugAnalytical Chemistry, 2008
- Spatial Regulation of Inflammation by Human Aortic Endothelial Cells in a Linear Gradient of Shear StressMicrocirculation, 2008
- Vascular RemodelingArteriosclerosis, Thrombosis, and Vascular Biology, 2007
- Microfluidic modulus for convenient cell culture and screening experimentsMicroelectronic Engineering, 2007
- Vascular mimetics based on microfluidics for imaging the leukocyte–endothelial inflammatory responseLab on a Chip, 2007
- Reversible assembling of microfluidic devices by aspirationMicroelectronic Engineering, 2006
- Dynamics of Drosophila embryonic patterning network perturbed in space and time using microfluidicsNature, 2005
- Continuous perfusion microfluidic cell culture array for high‐throughput cell‐based assaysBiotechnology and Bioengineering, 2004
- Transport, retention and fluorescent measurement of single biological cells studied in microfluidic chipsElectronic supplementary information (ESI) available: movie clip of cell retention. See http://www.rsc.org/suppdata/lc/b4/b400770k/Lab on a Chip, 2004
- The integrin VLA-4 supports tethering and rolling in flow on VCAM-1.Journal of Cell Biology, 1995