Radiomics analysis of dynamic carbon-11 methionine PET/computed tomography for differentiating benign and malignant musculoskeletal lesions: a preliminary clinical assessment
Open Access
- 29 October 2026
- journal article
- research article
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
Abstract
Objective: To evaluate the diagnostic performance of radiomics features and maximum standardized uptake value (SUV max ) extracted from dynamic carbon-11 methionine (C-11 MET) PET/computed tomography (PET/CT) in differentiating malignant from benign musculoskeletal lesions (MSLs) and compare their performance with apparent diffusion coefficient (ADC) values from magnetic resonance (MR) images. Methods: This retrospective study included 15 patients (malignant: seven and benign: eight) with MSLs who underwent dynamic C-11 MET PET scans [5–15 (phase 1), 15–25 (phase 2), and 25–35 (phase 3) min postinjection of C-11 MET] and conventional acquisition (35 min postinjection). For semiquantitative analysis of MET uptake, we used SUV max . For radiomics analysis, 109 features were extracted from the volume of interest for the entire target tumor in each dynamic phase. ADC values were measured from MR images. Diagnostic capacities were analyzed using the Mann–Whitney U test and receiver operating characteristic curve analyses. Results: SUV max for each dynamic phase and conventional acquisition was significantly higher in the malignant group than in the benign group ( P < 0.05). In radiomics analysis, 70, 69, and 69 features in phases 1, 2, and 3, respectively, were significantly different between malignant and benign groups [ P < 0.05; area under the ROC curves (AUCs) ≥ 0.821]. DeLong’s test showed no significant difference in AUCs between SUV max and any radiomics feature in each dynamic phase. ADC values did not differ significantly between malignant and benign groups. Conclusion: Dynamic C-11 MET PET/CT has potential for differentiating malignant from benign MSLs and supports the utility of radiomics analyses and SUV max .Keywords
Funding Information
- Japanese Society of Promotion of Science (JSPS) KAKENHI (Grant Number JP22K07696)
This publication has 27 references indexed in Scilit:
- Artificial intelligence: Deep learning in oncological radiomics and challenges of interpretability and data harmonizationPhysica Medica, 2021
- Peripheral nerve sheath tumor: differentiation of malignant from benign tumors with conventional and diffusion-weighted MRIEuropean Radiology, 2020
- The Image Biomarker Standardization Initiative: Standardized Quantitative Radiomics for High-Throughput Image-based PhenotypingRadiology, 2020
- 11C-methionine-PET for differentiating recurrent brain tumor from radiation necrosis: radiomics approach with random forest classifierScientific Reports, 2019
- Dietary methionine influences therapy in mouse cancer models and alters human metabolismNature, 2019
- Differentiation of peripheral nerve sheath tumors in patients with neurofibromatosis type 1 using diffusion-weighted magnetic resonance imagingNeuro-Oncology, 2019
- Conventional MR and diffusion-weighted imaging of musculoskeletal soft tissue malignancy: correlation with histologic gradingEuropean Radiology, 2018
- Diagnostic performance of conventional MRI parameters and apparent diffusion coefficient values in differentiating between benign and malignant soft-tissue tumoursClinical Radiology, 2017
- Investigation of the freely available easy-to-use software ‘EZR’ for medical statisticsBone Marrow Transplantation, 2012
- Quantifying tumour heterogeneity in 18F-FDG PET/CT imaging by texture analysisEuropean Journal of Nuclear Medicine and Molecular Imaging, 2012