Sphere-Enhanced Microwave Ablation (sMWA) Versus Bland Microwave Ablation (bMWA): Technical Parameters, Specific CT 3D Rendering and Histopathology
- 29 August 2014
- journal article
- research article
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 38 (2) , 442-452
Abstract
This study was designed to compare technical parameters during ablation as well as CT 3D rendering and histopathology of the ablation zone between sphere-enhanced microwave ablation (sMWA) and bland microwave ablation (bMWA). In six sheep-livers, 18 microwave ablations were performed with identical system presets (power output: 80 W, ablation time: 120 s). In three sheep, transarterial embolisation (TAE) was performed immediately before microwave ablation using spheres (diameter: 40 ± 10 μm) (sMWA). In the other three sheep, microwave ablation was performed without spheres embolisation (bMWA). Contrast-enhanced CT, sacrifice, and liver harvest followed immediately after microwave ablation. Study goals included technical parameters during ablation (resulting power output, ablation time), geometry of the ablation zone applying specific CT 3D rendering with a software prototype (short axis of the ablation zone, volume of the largest aligned ablation sphere within the ablation zone), and histopathology (hematoxylin-eosin, Masson Goldner and TUNEL). Resulting power output/ablation times were 78.7 ± 1.0 W/120 ± 0.0 s for bMWA and 78.4 ± 1.0 W/120 ± 0.0 s for sMWA (n.s., respectively). Short axis/volume were 23.7 ± 3.7 mm/7.0 ± 2.4 cm3 for bMWA and 29.1 ± 3.4 mm/11.5 ± 3.9 cm3 for sMWA (P Histopathology confirmed the signs of coagulation necrosis as well as early and irreversible cell death for bMWA and sMWA. For sMWA, spheres were detected within, at the rim, and outside of the ablation zone without conspicuous features. Specific CT 3D rendering identifies a larger ablation zone for sMWA compared with bMWA. The histopathological signs and the detectable amount of cell death are comparable for both groups. When comparing sMWA with bMWA, TAE has no effect on the technical parameters during ablation.Keywords
This publication has 19 references indexed in Scilit:
- Specific CT 3D rendering of the treatment zone after Irreversible Electroporation (IRE) in a pig liver model: the “Chebyshev Center Concept” to define the maximum treatable tumor sizeBMC Medical Imaging, 2014
- Long-term effectiveness of resection and radiofrequency ablation for single hepatocellular carcinoma ⩽3cm. Results of a multicenter Italian surveyJournal of Hepatology, 2013
- Meta-analysis of radiofrequency ablation in combination with transarterial chemoembolization for hepatocellular carcinomaWorld Journal of Gastroenterology, 2013
- Large primary hepatocellular carcinoma: Transarterial chemoembolization monotherapy versus combined transarterial chemoembolization‐percutaneous microwave coagulation therapyJournal of Gastroenterology and Hepatology, 2012
- CT-guided Bipolar and Multipolar Radiofrequency Ablation (RF Ablation) of Renal Cell Carcinoma: Specific Technical Aspects and Clinical ResultsCardioVascular and Interventional Radiology, 2012
- Effect of Tissue Perfusion on Microwave Ablation: Experimental in Vivo Study in Porcine KidneysJournal of Vascular and Interventional Radiology, 2011
- Microwaves create larger ablations than radiofrequency when controlled for power in ex vivo tissueMedical Physics, 2010
- Microwave Ablation Technology: What Every User Should KnowCurrent Problems in Diagnostic Radiology, 2009
- Immediate and long-term CT appearances following radiofrequency ablation of renal tumoursClinical Radiology, 2008
- Microwave Ablation: Principles and ApplicationsRadioGraphics, 2005