Femoral neck fracture osteosynthesis by the biplane double-supported screw fixation method (BDSF) reduces the risk of fixation failure: clinical outcomes in 207 patients
Authors:
Open Access
- 8 April 2017
- journal article
- research article
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 137 (6) , 779-788
Abstract
Introduction Osteosynthesis of femoral neck fractures is related up to 46% rate of complications. The novel method of biplane double-supported screw fixation (BDSF; Filipov’s method) offers better stability using three medially diverging cannulated screws with two of them buttressed on the calcar. Biomechanically, the most effective component is the distal screw placed at steeper angle and supported on a large area along the distal and posterior cortex of the femoral neck following its spiral anterior curve. Thereby, BDSF achieves the strongest possible distal-posterior cortical support for the fixation construct, which allows for immediate full weight-bearing. The aim of this study was to evaluate the outcomes from the first 5-year period of BDSF clinical application. Materials and methods Subject of this retrospective study were 207 patients with displaced Garden III–IV femoral neck fractures treated with BDSF. Three 7.3-mm cannulated screws were laid in two medially diverging oblique planes. The distal and the middle screws were supported on the calcar. The distal screw had additional support on the posterior neck cortex. Results The outcomes in 207 patients were analysed in 29.6 ± 16.8 months follow-up. Bone union occurred in 96.6% of the cases (males 97.6%, females 96.4%, P = 0.99). Rate of nonunion was 3.4%, including fixation failure (2.4%), pseudoarthrosis (0.5%) and nonunion with AVN (0.5%). Rate of AVN was 12.1% (males 4.8%, females 13.9%, P = 0.12). Modified Harris hip score was 86.2 ± 18.9 (range 10–100), with no significant difference between genders, P = 0.07. Older patients were admitted with significantly more comorbidities (P = 0.001), and on follow-up they were significantly less mobile (P = 0.005) and had significantly more difficulties to put socks and shoes on (P < 0.001). Conclusions By providing additional cortical support, the novel BDSF method enhances femoral neck fracture fixation strength.Keywords
This publication has 31 references indexed in Scilit:
- Biplane double-supported screw fixation (F-technique): a method of screw fixation at osteoporotic fractures of the femoral neckEuropean Journal of Orthopaedic Surgery & Traumatology, 2011
- Long-term follow-up of replacement compared with internal fixation for displaced femoral neck fracturesThe Journal of Bone and Joint Surgery. British volume, 2010
- Incidence of Fracture-healing Complications after Femoral Neck FracturesClinical Orthopaedics and Related Research, 2007
- Primary arthroplasty is better than internal fixation of displaced femoral neck fractures: A meta-analysis of 14 randomized studies with 2,289 patientsActa Orthopaedica, 2006
- Internal fixation compared with total hip replacement for displaced femoral neck fractures in the elderlyThe Journal of Bone and Joint Surgery. British volume, 2003
- Fixation of fractures of the femoral neckThe Journal of Bone and Joint Surgery. British volume, 2003
- A Treatment for Fracture of the Neck of the FemurClinical Orthopaedics and Related Research, 2002
- Fixation of femoral neck fractures Comparison of the Uppsala and von Bahr screwsActa Orthopaedica, 1989
- Early loss of fixation of femoral neck fractures Comparison of three devices in 244 casesActa Orthopaedica, 1989
- Femoral Neck Fractures in Young AdultsActa Orthopaedica, 1982