Nonmodular Flexible Press-Fit Cup in Primary Total Hip Arthroplasty
Authors:
- Gu PingGPGu Ping
- Walter DickWDWalter Dick
- Erwin W MorscherEMErwin W Morscher
- 1 August 2007
- journal article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 461, 114-121
Abstract
The key rationale for a nonmodular flexible press-fit cup was to maximize long-term stability with a cementless, porous metal-coated cup that is low in stiffness (no metal shell) and to achieve fixation solely through biradial eccentricity between the cup and the acetabular cavity. We asked whether the promising results achieved at 5 and 10 years would be maintained at 15 years. We reviewed 261 patients who received the first 280 Morscher Press-Fit Cups. One hundred twenty patients (126 hips) died. One hundred one patients (112 hips) had a clinical and radiographic followup after a minimum of 13.5 years (mean, 14.7 years; range, 13.5-17.0 years). Twenty-four patients with 26 hips were clinically examined or interviewed by telephone. Three of the 101 patients were lost to followup. We judged the results excellent or good in 96% of the hips. The 15-year overall survivorship was 95.3% and with the end point of aseptic loosening, the survivorship was 97.5%. Wear was greater in cups with an inclination greater than 45 degrees and in metal-polyethylene pairings compared with ceramic-polyethylene pairings. This cup design performs well over the long term.Keywords
This publication has 41 references indexed in Scilit:
- Ten-year survival of the MS-30 matt-surfaced cemented stemThe Journal of Bone and Joint Surgery. British volume, 2005
- A comparison of polyethylene wear rates between cemented and cementless cupsThe Journal of Bone and Joint Surgery. British volume, 2004
- Harris Galante cementless acetabular replacement in avascular necrosisThe Journal of Bone and Joint Surgery. British volume, 2001
- Cementless Acetabular Replacement in the YoungClinical Orthopaedics and Related Research, 2000
- Clinical and radiographic evaluation of the Harris-Galante CupThe Journal of Arthroplasty, 2000
- Primary Cementless Acetabular Reconstruction in Patients Younger Than 50 Years OldClinical Orthopaedics and Related Research, 1997
- A quantitative in vitro assessment of fit and screw fixation on the stability of a cementless hemispherical acetabular componentThe Journal of Arthroplasty, 1994
- Evaluation of acetabular stability in uncemented prosthesesThe Journal of Arthroplasty, 1991
- The Relationship of the Intrapelvic Vasculature to the AcetabulumClinical Orthopaedics and Related Research, 1990
- Nonparametric Estimation from Incomplete ObservationsJournal of the American Statistical Association, 1958