L-cysteine-capped CdTe QD-based sensor for simple and selective detection of trinitrotoluene
Authors:
- Zhang ChenZCZhang Chen
- Yejuan HeYHYejuan He
- Hailan LinHLHailan Lin
- Pengtao ShengPSPengtao Sheng
- Chengbin LiuChengbin Liu
- Shenglian LuoSLShenglian Luo
- Qingyun CaiQCQingyun Cai
- 5 March 2010
- journal article
- Published by IOP Publishing in Nanotechnology
- Vol. 21 (12) , 125502
Abstract
Trinitrotoluene, usually known as TNT, is a kind of chemical explosive with hazardous and toxic effects on the environment and human health. National and societal security concerns have dictated an increasing need for the analytical detection of TNT with rapidity, high sensitivity and low cost. This work demonstrates a novel method using L-cysteine-capped CdTe quantum dots (QDs) to assay TNT, based on the formation of a Meisenheimer complex between TNT and cysteine. The fluorescence (FL) of quantum dots quench because electrons of the QDs transfer to the TNT molecules via the formation of a Meisenheimer complex. TNT can be detected with a low detection limit of 1.1 nM. Studies on the selectivity of this method show that only TNT can generate an intense signal response. The synthesized QDs are excellent nanomaterials for TNT detection. In addition, TNT in soil samples is also analyzed by the proposed method.Keywords
This publication has 24 references indexed in Scilit:
- Gold Nanoparticle Based Label-Free SERS Probe for Ultrasensitive and Selective Detection of TrinitrotolueneJournal of the American Chemical Society, 2009
- Ultrasensitive detection of TNT in soil, water, using enhanced electrogenerated chemiluminescenceAnalytica Chimica Acta, 2009
- A Simple Assay for Direct Colorimetric Visualization of Trinitrotoluene at Picomolar Levels Using Gold NanoparticlesAngewandte Chemie International Edition, 2008
- Imprinting of Molecular Recognition Sites through Electropolymerization of Functionalized Au Nanoparticles: Development of an Electrochemical TNT Sensor Based on π-Donor−Acceptor InteractionsJournal of the American Chemical Society, 2008
- Comparison of biomarkers in workers exposed to 2,4,6-trinitrotolueneBiomarkers, 2007
- TNT Detection Using Multiplexed Liquid Array Displacement ImmunoassaysAnalytical Chemistry, 2006
- Chloride Effect on TNT Degradation by Zerovalent Iron or Zinc during Water TreatmentEnvironmental Science & Technology, 2004
- Detection of Nitroaromatic Explosives Based on Photoluminescent Polymers Containing MetallolesJournal of the American Chemical Society, 2003
- Demonstration of Four Immunoassay Formats Using the Array BiosensorAnalytical Chemistry, 2002
- Broadening the antibody specificity by hapten design for an enzyme-linked immunoassay as an improved screening method for the determination of nitroaromatic residues in soilsAnalytica Chimica Acta, 1995