Relationship between Bispectral Index, electroencephalographic state entropy and effect-site EC 50 for propofol at different clinical endpoints
Authors:
- M. IannuzziMIM. Iannuzzi
- E. IannuzziEIE. Iannuzzi
- F. RossiFRF. Rossi
- L. BerrinoLBL. Berrino
- M. ChiefariMCM. Chiefari
- 1 April 2005
- journal article
- duplicate publication
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 94 (4) , 492-495
Abstract
State entropy (SE) is a newly available monitor for depth of anaesthesia. We investigated whether the relationship between predicted effect-site propofol concentration and Bispectral Index (BIS) and SE values is useful for predicting loss of verbal contact and loss of consciousness during steady-state conditions. Twenty unpremedicated patients undergoing elective major abdominal surgery were recruited. A target-controlled infusion of propofol was administered using Schneider's pharmacokinetic model. The propofol infusion was set at an initial site effect concentration of 1.0 microg ml(-1) and increased by 1.0 microg ml(-1) steps every 4 min up to 6.0 microg ml(-1). A 4-min interval was chosen to ensure that steady-state effect-site concentrations were obtained. Propofol site effect concentrations and BIS and SE values were recorded at loss of verbal contact (LVC) and loss of consciousness (LOC). Population values for predicted effect-site concentrations at the clinical endpoints were estimated and correlated with BIS and SE values. For LVC, the effect-site concentration for 90% of patients was 1.1 (1.1-3.2) microg ml(-1) and for LOC it was 2.8 (2.8-5.65) microg ml(-1). LVC occurred in 90% of patients at a BIS value of 70.2 (70.2-90.2) and an SE value of 60.3 (60.3-75.5), and LOC occurred at a BIS value of 38.2 (38.2-70.4) and an SE value of 42.2 (42.2-60.4). LVC and LOC occurred within a defined range of predicted effect-site concentrations. SE had a smaller range than BIS and greater correlation with effect-site concentration and may be more useful than BIS in predicting both LVC and LOC.Keywords
This publication has 16 references indexed in Scilit:
- Correlation of Approximate Entropy, Bispectral Index, and Spectral Edge Frequency 95 (SEF95) with Clinical Signs of “Anesthetic Depth” during Coadministration of Propofol and RemifentanilAnesthesiology, 2003
- Relationship between bispectral index, auditory evoked potential index and effect-site EC 50 for propofol at two clinical end-points †British Journal of Anaesthesia, 2003
- Performance of the ARX-derived Auditory Evoked Potential Index as an Indicator of Anesthetic DepthAnesthesiology, 2002
- Comparison of Plasma Compartment versus Two Methods for Effect Compartment–controlled Target-controlled Infusion for PropofolAnesthesiology, 2000
- The Influence of Age on Propofol PharmacodynamicsAnesthesiology, 1999
- The Influence of Method of Administration and Covariates on the Pharmacokinetics of Propofol in Adult VolunteersAnesthesiology, 1998
- Measuring the Performance of Anesthetic Depth IndicatorsAnesthesiology, 1996
- Anesthetic Depth Defined Using Multiple Noxious Stimuli during Isoflurane/Oxygen Anesthesia I. Motor ReactionsAnesthesiology, 1994
- Algorithms to rapidly achieve and maintain stable drug concentrations at the site of drug effect with a computer-controlled infusion pumpJournal of Pharmacokinetics and Biopharmaceutics, 1992
- Intravenous propofol anaesthesia using a computerised infusion systemAnaesthesia, 1990