Development and Evaluation of a Loop-Mediated Isothermal Amplification Assay for the Detection of Adenovirus 40 and 41
- 4 February 2015
- journal article
- research article
- Published by Springer Nature in Food and Environmental Virology
- Vol. 7 (3) , 276-285
Abstract
Human adenoviruses (hAdVs) of subgroup F (enteric serotypes 40 and 41) display characteristic gut tropism, in vivo, fastidious growth characteristics in cell culture, and are estimated to be associated with 5–20 % worldwide of acute gastroenteritis cases among infants and young children. Adequate hAdV gastroenteritis case management requires laboratory-based diagnosis. The present study aimed to the development and evaluation of a simple and cost-effective, one-step, single-tube adenovirus type 40/41 specific loop-mediated isothermal amplification (LAMP) assay for the detection of hAdV40/41 DNA in environmental and/or clinical samples, since no LAMP assay has previously been reported for the detection of these virus types. The assay targeted the hexon gene and had the advantages of being rapid, simple, specific, and sensitive. Results could be obtained within 60 min, under isothermal conditions at 69 °C. The detection limits for hAdV genomes were between 50 and 100 copies/reaction for hAdV40 and hAdV41, and no cross-reactions with other selected viruses, were found. The assay was evaluated with clinical as well as environmental samples. The developed assay is expected to provide a potential molecular tool in obtaining greater knowledge of the hAdV40/41 importance in the epidemiology and clinical manifestations of gastroenteritis.Keywords
This publication has 53 references indexed in Scilit:
- Molecular evolution of human adenovirusesScientific Reports, 2013
- Epidemiological investigation of two parallel gastroenteritis outbreaks in school settingsBMC Public Health, 2013
- Real-Time Qualitative PCR for 57 Human Adenovirus Types from Multiple Specimen SourcesJournal of Clinical Microbiology, 2012
- Evaluation and Verification of the Seeplex Diarrhea-V ACE Assay for Simultaneous Detection of Adenovirus, Rotavirus, and Norovirus Genogroups I and II in Clinical Stool SpecimensJournal of Clinical Microbiology, 2011
- Development of an optimized method for the detection of airborne viruses with real-time PCR analysisVirology Journal, 2011
- Molecular detection of multiple viral targets in untreated urban sewage from GreeceVirology Journal, 2011
- Multiplex reverse transcription PCR Luminex assay for detection and quantitation of viral agents of gastroenteritisJournal of Clinical Virology, 2011
- Quantitative Detection of Human Adenoviruses in Wastewater and Combined Sewer Overflows Influencing a Michigan RiverApplied and Environmental Microbiology, 2010
- Quantification and Stability of Human Adenoviruses and Polyomavirus JCPyV in Wastewater MatricesApplied and Environmental Microbiology, 2006
- Real-Time Reverse Transcription-PCR for Detection of Rotavirus and Adenovirus as Causative Agents of Acute Viral Gastroenteritis in ChildrenJournal of Clinical Microbiology, 2006