The effects of gel-based manicure on pulse oximetry
Authors:
- Jlj YekJYJlj Yek
- Hr AbdullahHAHr Abdullah
- J GohJGJ Goh
- Yw ChanYCYw Chan
- 1 August 2019
- journal article
- research article
- Published by Wolters Kluwer Health in Singapore Medical Journal
- Vol. 60 (8) , 432-435
Abstract
Pulse oximetry is the standard monitoring technique of functional oxygen saturation (SpO2). As the use of fingernail polish has been described to alter SpO2 readings, its removal is commonly recommended prior to measurement. Gel-based manicures have gained popularity in recent years due to their attractiveness and longevity. However, the removal of gel nail polish requires a specialised procedure. Valuable time and resources can be saved if removal can be avoided. To our knowledge, there are no available studies on the effect of gel-based manicures on pulse oximetry readings. Hence, we evaluated the effect with two oximeters, using different technology and wavelength combinations. 17 healthy female adult volunteers were recruited for this single-blind randomised controlled trial. Subjects with hypothermia, hypotension, poor plethysmographic waveform and nail pathology were excluded. Colours tested were: black, purple, navy blue, green, light blue, white, yellow, orange, pink and red. Pulse oximetry was measured at 15- and 30-second intervals using two different pulse oximeters, the Philips M1191BL and Masimo SET®. Means were compared using paired t-tests. Using the Masimo oximeter, light blue (ΔM = 0.97% ± 0.96%; p = 0.001) and orange (ΔM = 0.76 ± 1.17%; p = 0.016) gel nail polish resulted in a statistically significant increase from baseline SpO2 readings. With the Philips oximeter, the limits of agreement ranged from 2% for pink to 17% for black, indicating imprecision. Gel-based manicures can result in overestimations of actual readings, delaying detection of hypoxaemia. Gel nail polish should be routinely removed or an alternative monitoring technique sought.Keywords
This publication has 10 references indexed in Scilit:
- CONSORT 2010 statement: Updated guidelines for reporting parallel group randomised trialsInternational Journal of Surgery, 2011
- Nail Polish Does Not Significantly Affect Pulse Oximetry Measurements in Mildly Hypoxic SubjectsRespiratory Care, 2008
- Artificial acrylic finger nails may alter pulse oximetry measurementResuscitation, 2007
- Does fingernail polish affect pulse oximeter readings?Intensive and Critical Care Nursing, 2007
- Effect of nail polish on oxygen saturation determined by pulse oximetry in critically ill patientsResuscitation, 2007
- Measuring agreement in method comparison studiesStatistical Methods in Medical Research, 1999
- Potential errors in pulse oximetry III: Effects of interference, dyes, dyshaemoglobins and other pigments*Anaesthesia, 1991
- Pulse Oximeter Failure Thresholds in Hypotension and VasoconstrictionAnesthesiology, 1990
- The Effect of Nail Polish on Pulse OximetryAnesthesia & Analgesia, 1988
- Nail Polish Color Can Affect Pulse Oximeter SaturationAnesthesiology, 1988