Abstract
Volatile organic compounds (VOCs) are valuable health indicators, with synthetic breath biomarkers offering rapid and disease-specific diagnostics. However, their 3 electric field enhancement, were generated between a gold film and gold-silica core-shell nanoparticle assemblies using electric field-driven evaporation. Oxygen plasma treatment hydroxylated the silica, enabling water-mediated hydrogen bonding that strengthened PFP adsorption, confirmed by density functional theory. This mechanism improved SERS sensitivity by 104-fold, enabling ppb level PFP detection in mouse bronchial fluid and establishing a VOC capturing SERS platform for breath-based diagnostics.
Funding Information
  • National Institute of General Medical Sciences (T32GM144273)
  • Open Philanthropy Project (3860485)

This publication has 56 references indexed in Scilit: