Polarity effects on place pitch and loudness for three cochlear-implant designs and at different cochlear sites
- 1 July 2013
- journal article
- research article
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 134 (1) , 503-509
Abstract
Users of Advanced Bionics, MedEl, and Cochlear Corp. implants balanced the loudness of trains of asymmetric pulses of opposite polarities presented in monopolar mode. For the Advanced Bionics and MedEl users the pulses were triphasic and consisted of a 32-μs central phase flanked by two 32-μs phases of opposite polarity and half the amplitude. The central phase was either anodic (TP-A) or cathodic (TP-C). For the Cochlear Corp. users, pulses consisted of two 32-μs phases of the same polarity separated by an 8-μs gap, flanked by two 32-μs phases of the opposite polarity, each of which was separated from the central portion by a 58-μs gap. The central portion of these quadraphasic pulses was either anodic (QP-A) or cathodic (QP-C), and all phases had the same amplitude. The current needed to achieve matched loudness was lower for the anodic than for the cathodic stimuli. This polarity effect was similar across all electrode locations studied, including the most apical electrode of the MedEl device which stimulates the very apex of the cochlea. In addition, when quadraphasic pulses were presented in bipolar mode, listeners reported hearing a lower pitch when the central portion was anodic at the more apical, than at the more basal, electrode. The results replicate previous reports that, unlike the results of most animal studies, human cochlear implant listeners are more sensitive to anodic than to cathodic currents, and extend those findings to a wider range of cochlear sites, implant types, and pulse shapes.Keywords
This publication has 27 references indexed in Scilit:
- Place-pitch manipulations with cochlear implantsThe Journal of the Acoustical Society of America, 2012
- Extending the Limits of Place and Temporal Pitch Perception in Cochlear Implant UsersJournal of the Association for Research in Otolaryngology, 2010
- The upper limit of temporal pitch for cochlear-implant listeners: Stimulus duration, conditioner pulses, and the number of electrodes stimulatedThe Journal of the Acoustical Society of America, 2010
- Forward-masking patterns produced by symmetric and asymmetric pulse shapes in electric hearingThe Journal of the Acoustical Society of America, 2010
- Higher Sensitivity of Human Auditory Nerve Fibers to Positive Electrical CurrentsJournal of the Association for Research in Otolaryngology, 2008
- Multichannel Cochlear Implants: Relation of Histopathology to PerformanceThe Laryngoscope, 2006
- Asymmetric Pulses in Cochlear Implants: Effects of Pulse Shape, Polarity, and RateJournal of the Association for Research in Otolaryngology, 2006
- Excitation of Central Nervous System Neurons by Nonuniform Electric FieldsBiophysical Journal, 1999
- Loudness perception with pulsatile electrical stimulation: The effect of interpulse intervalsThe Journal of the Acoustical Society of America, 1998
- Which elements are excited in electrical stimulation of mammalian central nervous system: A reviewBrain Research, 1975