X-ray luminescence computed tomography imaging based on X-ray distribution model and adaptively split Bregman method
Authors:
Open Access
- 23 June 2015
- journal article
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 6 (7) , 2649-2663
Abstract
X-ray luminescence computed tomography (XLCT) has become a promising imaging technology for biological application based on phosphor nanoparticles. There are mainly three kinds of XLCT imaging systems: pencil beam XLCT, narrow beam XLCT and cone beam XLCT. Narrow beam XLCT can be regarded as a balance between the pencil beam mode and the cone-beam mode in terms of imaging efficiency and image quality. The collimated X-ray beams are assumed to be parallel ones in the traditional narrow beam XLCT. However, we observe that the cone beam X-rays are collimated into X-ray beams with fan-shaped broadening instead of parallel ones in our prototype narrow beam XLCT. Hence we incorporate the distribution of the X-ray beams in the physical model and collected the optical data from only two perpendicular directions to further speed up the scanning time. Meanwhile we propose a depth related adaptive regularized split Bregman (DARSB) method in reconstruction. The simulation experiments show that the proposed physical model and method can achieve better results in the location error, dice coefficient, mean square error and the intensity error than the traditional split Bregman method and validate the feasibility of method. The phantom experiment can obtain the location error less than 1.1 mm and validate that the incorporation of fan-shaped X-ray beams in our model can achieve better results than the parallel X-rays.Keywords
Funding Information
- Natural Science Foundation of Beijing Municipality (No. 7142012)
- Fundamental Research Funds for the Central Universities
- National Basic Research and Development Program of China (973) (No. 2011CB707702)
- National Key Technology Support Program (No. 2012BAI23B06)
- National Natural Science Foundation of China (NSFC) (No.61471279, No.81090272, No.81227901)
This publication has 35 references indexed in Scilit:
- Experimental Three-Dimensional Bioluminescence Tomography Reconstruction Using the lp RegularizationAdvanced Science Letters, 2012
- Limited-angle x-ray luminescence tomography: methodology and feasibility studyPhysics in Medicine & Biology, 2011
- Spectrally resolving and scattering-compensated x-ray luminescence∕fluorescence computed tomographyJournal of Biomedical Optics, 2011
- Quantitative fluorescence tomography using a combined tri-modality FT/DOT/XCT systemOptics Express, 2010
- Luminescent rare earth nanomaterials for bioprobe applicationsDalton Transactions, 2008
- Fast iterative image reconstruction methods for fully 3D multispectral bioluminescence tomographyPhysics in Medicine & Biology, 2008
- Preparation and luminescence property of Gd2O2S:Tb X-ray nano-phosphors using the complex precipitation methodJournal of Alloys and Compounds, 2007
- Digimouse: a 3D whole body mouse atlas from CT and cryosection dataPhysics in Medicine & Biology, 2007
- The inverse source problem based on the radiative transfer equation in optical molecular imagingJournal of Computational Physics, 2005
- Measures of the Amount of Ecologic Association Between SpeciesEcology, 1945