The Use of Outrigger System in Steel Plate Shear Wall Structures
- 1 June 2015
- journal article
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 18 (6) , 853-872
Abstract
The use of capacity design method (CDM) in steel plate shear wall (SPSW) structures results in large vertical boundary elements (VBEs). One way to reduce the force demands on VBEs is to employ outrigger beams in the adjacent spans of SPSW. In this paper, twelve dual SPSW-moment resisting frames are designed and analyzed by FE method to investigate the effects of outrigger system on the behavior of SPSW structures. Results show that outrigger beams can transfer considerable amount of axial force and bending moment from VBEs to the outer spans columns; resulting in smaller sections for VBEs. In addition, the most effective stories to employ outrigger beams are shown to be the stories which undergo larger drifts. Outrigger system also results in a more uniform distribution of structural stiffness along the height of SPSW frames. Furthermore, a design procedure based on the direct analysis method is proposed for the design of SPSW-Outrigger system. The procedure eliminates the excessive capacities in CDM, while satisfying all CDM requirements.Keywords
This publication has 11 references indexed in Scilit:
- Comparative Study on Steel Plate Shear Walls Used in a High-Rise BuildingJournal of Structural Engineering, 2013
- Tall building with steel plate shear walls subject to load reversalThe Structural Design of Tall and Special Buildings, 2011
- Seismic behavior of code designed steel plate shear wallsEngineering Structures, 2011
- Characteristics of the wall–frame interaction in steel plate shear wallsJournal of Constructional Steel Research, 2010
- Steel Plate Shear Walls: Efficient Structural Solution for Slender High-Rise in ChinaAIP Conference Proceedings, 2008
- A proposal for the classification of structural systems of tall buildingsBuilding and Environment, 2007
- Cyclic behavior of low yield point steel shear wallsThin-Walled Structures, 2006
- Experimental Investigation of Light-Gauge Steel Plate Shear WallsJournal of Structural Engineering, 2005
- Analysis of high‐rise braced frames with outriggersThe Structural Design of Tall and Special Buildings, 2003
- Cyclic Test of Four-Story Steel Plate Shear WallJournal of Structural Engineering, 1998