Reduction of Intraocular Pressure and Aqueous Outflow Resistance After Modified 360-degree Suture Trabeculotomy
- 12 October 2022
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 32 (3) , 204-209
Abstract
Précis: Decreasing aqueous outflow resistance at trabecular meshwork is the main mechanism of modified 360-degree suture trabeculotomy (ST), and the preoperative C-value, which shows aqueous outflow resistance, is likely to be useful for predicting intraocular pressure (IOP) reduction. Purpose: To clarify the mechanism of IOP reduction and the preoperative prognostic predictor of modified 360-degree ST. Materials and Methods: Forty-three eyes of 32 patients with glaucoma who underwent ST at Hokkaido University Hospital between April 2017 and February 2020 were enrolled. The records of postoperative IOP and coefficient of aqueous outflow (C-value) after ST were reviewed from clinical charts retrospectively. Preoperative IOP and C-values were also reviewed and considered as the baseline. Results: Although the differences were not significant, IOP decreased to 15.4±3.3 mm Hg at 3 months (P=0.10) and 16.1±3.8 mm Hg at 6 months (P=0.21). In addition, there were significant decreases in anti-glaucoma medication scores at both 3 and 6 months after surgery (PPPr=−0.49 Pr=−0.46 P0.17) (PP<0.05) at 6 months. Conclusions: Increased conventional outflow by the elimination of the aqueous outflow resistance at the trabecular meshwork is the main mechanism of IOP reduction after ST. Preoperative examination of tonographic outflow facility may be useful for predicting the IOP reduction and outcome of ST.Keywords
This publication has 19 references indexed in Scilit:
- Steroid-induced glaucoma: Epidemiology, pathophysiology, and clinical managementSurvey of Ophthalmology, 2020
- Modified 360-degree suture trabeculotomy combined with phacoemulsification and intraocular lens implantation for glaucoma and coexisting cataractJournal of Cataract & Refractive Surgery, 2016
- Measurement of episcleral venous pressureExperimental Eye Research, 2011
- 360° Trabeculotomy for Primary Congenital GlaucomaArchives of Ophthalmology (1950), 1995
- Surgical Effects of Trabeculotomy Ab Externo on Adult Eyes With Primary Open Angle Glaucoma and Pseudoexfoliation SyndromeArchives of Ophthalmology (1950), 1993
- Trabeculotomy AB ExternoAmerican Journal of Ophthalmology, 1962
- Further Studies on Facility of Flow Through the Trabecular MeshworkArchives of Ophthalmology (1950), 1958
- Clinical Tonography: The Scleral Rigidity CorrectionAmerican Journal of Ophthalmology, 1958
- CLINICAL MEASUREMENTS OF AQUEOUS OUTFLOWArchives of Ophthalmology (1950), 1951
- TONOGRAPHIC METHOD FOR MEASURING THE FACILITY AND RATE OF AQUEOUS FLOW IN HUMAN EYESArchives of Ophthalmology (1950), 1950