A Predictive Model for Differential Diagnosis of Cardiogenic and Non‐cardiogenic Dyspnea in Patients with Chronic Kidney Disease Based on Cardio and Lung Ultrasound Features: A Single‐Center Observational Study
- 27 May 2026
- journal article
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 45 (10) , 2311-2327
Abstract
Objectives: Lung ultrasound (LUS) quantifying B‐lines is valuable to assess fluid status during hemodialysis. However, B‐lines may indicate not only cardiogenic pulmonary edema (CPE) but also non‐cardiogenic pulmonary diseases, such as pneumonia or interstitial lung disease, posing challenges to guiding fluid therapy decisions. We developed a combined cardiac‐LUS diagnostic model to differentiate these etiologies, aiming to prevent misdiagnosis and optimize treatment. Methods: This retrospective observational study enrolled chronic kidney disease (CKD) stage 3–5 patients divided into training and validation cohorts. Participants were classified into CPE group or non‐cardiogenic dyspnea (NCD) group. Multivariable logistic regression identified discriminative echocardiographic and LUS parameters to build a diagnostic model. Predictive performance was assessed using receiver operator characteristic (ROC), calibration and decision curve analysis. A simplified β‐weighted scoring system was developed and evaluated. Results: This retrospective study analyzed 215 training and 56 validation participants. Multivariable regression identified E/e′ (OR 1.180, 95% CI 1.067–1.304, p = .001), inferior vena cava diameter (OR 1.240, 95% CI 1.023–1.503, p = .029), bilateral symmetric B‐pattern (OR 9.720, 95% CI 2.707–34.899, p < .001), bilateral continuous B‐pattern (OR 13.777, 95% CI 3.666–51.770, p < .001), ≥1 irregular pleural line region (OR 0.078, 95% CI 0.018–0.326, p < .001), ≥1 consolidation region (OR 0.039, 95% CI 0.008–0.196, p < .001), ≥1 pleural effusion region (OR 4.732, 95% CI 1.148–19.510, p = .032) as independent CPE predictors. The nomogram showed good discrimination, with area under the curve (AUC) of 0.9703 (training) and 0.8910 (validation). The β‐weighted scoring system (cut‐off as 42.99 scores) showed an AUC of 0.968 (training) and 0.888 (validation). Conclusion: The nomogram model demonstrated that the ultrasound parameters and β‐weighted scoring system possess reliable clinical application value and high predictive accuracy.Keywords
This publication has 50 references indexed in Scilit:
- Acute Pulmonary Interstitial Fibrosis Caused by Anti‐GBM Disease Combined With ANCA‐Associated Vasculitis—The Role of Combined Cardiopulmonary Ultrasound in Early Differential Diagnosis and Evaluation: A Case ReportJournal of Clinical Ultrasound, 2025
- ESICM—ESPNIC international expert consensus on quantitative lung ultrasound in intensive careIntensive Care Medicine, 2025
- Accuracy of lung ultrasound performed with handheld ultrasound device in internal medicine: an observational studyJournal of Ultrasound, 2024
- New International Guidelines and Consensus on the Use of Lung UltrasoundJournal of Ultrasound in Medicine, 2022
- Using the lung ultrasound score to monitor disease progression for COVID-19-associated ARDSIntensive Care Medicine, 2021
- Comparative study of lung ultrasound and chest computed tomography scan in the assessment of severity of confirmed COVID-19 pneumoniaIntensive Care Medicine, 2020
- Findings of lung ultrasonography of novel corona virus pneumonia during the 2019–2020 epidemicIntensive Care Medicine, 2020
- Diagnostic Accuracy of Point-of-Care Lung Ultrasonography and Chest Radiography in Adults With Symptoms Suggestive of Acute Decompensated Heart FailureJAMA Network Open, 2019
- International evidence-based recommendations for point-of-care lung ultrasoundIntensive Care Medicine, 2012
- Cardiovascular and Noncardiovascular Mortality Among Patients Starting DialysisJAMA, 2009