Abstract
Stable isotopic characterization of chlorine in chlorinated aliphatic pollution is potentially very valuable for risk assessment and monitoring remediation or natural attenuation. The approach has been underused because of the complexity of analysis and the time it takes. We have developed a new method that eliminates sample preparation. Gas chromatography produces individually eluted sample peaks for analysis. The He carrier gas is mixed with Ar and introduced directly into the torch of a multicollector ICPMS. The MC-ICPMS is run at a high mass resolution of ≥10 000 to eliminate interference of mass 37 ArH with Cl. The standardization approach is similar to that for continuous flow stable isotope analysis in which sample and reference materials are measured successively. We have measured PCE relative to a laboratory TCE standard mixed with the sample. Solvent samples of 200 nmol to 1.3 μmol (24−165 μg of Cl) were measured. The PCE gave the same value relative to the TCE as measured by the conventional method with a precision of 0.12‰ (2× standard error) but poorer precision for the smaller samples.Keywords
This publication has 12 references indexed in Scilit:
- Determination of inorganic chlorine stable isotopes by continuous flow isotope ratio mass spectrometryRapid Communications in Mass Spectrometry, 2004
- On-Line Technique for the Determination of the δ37Cl of Inorganic and Total Organic Cl in Environmental SamplesAnalytical Chemistry, 2004
- Chlorine stable isotope measurements of chlorinated aliphatic hydrocarbons by thermal ionization mass spectrometryAnalytica Chimica Acta, 2002
- Characterisation of chlorinated hydrocarbons from chlorine and carbon isotopic compositions: scope of application to environmental problemsApplied Geochemistry, 2001
- Chlorine Stable Isotopes: A Comparison of Dual Inlet and Thermal Ionization Mass Spectrometric MeasurementsAnalytical Chemistry, 2000
- Isotopic characterization of chlorinated solvents—laboratory and field resultsOrganic Geochemistry, 1999
- Contrasting carbon isotope fractionation during biodegradation of trichloroethylene and toluene: Implications for intrinsic bioremediationOrganic Geochemistry, 1999
- Sequential Determination of Chlorine and Carbon Isotopic Composition in Single Microliter Samples of Chlorinated SolventAnalytical Chemistry, 1997
- Stable chlorine and carbon isotope measurements of selected chlorinated organic solventsApplied Geochemistry, 1995
- Natural chlorine isotope variationsNature, 1984