Dissolution of peripheral arterial thrombi by ultrasound.
Authors:
- 1 October 1991
- journal article
- abstracts
- Published by Wolters Kluwer Health in Circulation
- Vol. 84 (4) , 1680-1688
Abstract
BACKGROUND: We have previously shown that continuous-wave ultrasound can rapidly dissolve human thrombi in vitro, with 99% of all residual particles measuring less than 10 microns in diameter. To assess the effects of pulsed-wave ultrasound energy on whole blood clots, 1) in vitro studies were preformed to assess precisely the rates of clot disruption and to quantify particulate size, and 2) in vivo studies were performed to assess the efficacy and safety of catheter-delivered ultrasound for intra-arterial thrombus dissolution. METHODS AND RESULTS: In vitro, we studied 50 samples of human whole blood clots and using an 89-cm-long wire probe, applied pulse-wave energies from 8 to 23 W. The corresponding peak-to-peak tip displacement range was 63.5 - 102 microns. We studied arterial thrombosis in vivo in 21 canine superficial femoral arteries. To produce an acute thrombosis, 200 units of thrombin followed by 2 ml of 72-hour-old autologous clot were injected into a 5-7-cm segment of femoral artery and left to coagulate for 2 hours. Ultrasound energy was intermittently applied at a frequency of 20 kHz with a prototype ultrasound wire ensheathed in a catheter and directed to clots by fluoroscopy. In nine cases, angioscopic guidance was used to put the probe into direct contact with the intra-arterial thromboses. In vitro clot dissolution times were inversely related to the ultrasound power output (r = 0.95). All in vivo canine thromboses were disrupted in 4 minutes or less. All successful recanalizations were confirmed by angiography and in nine cases by angioscopy as well. Angioscopy demonstrated that probe activation caused rapid clot disruption. Histological studies of the vessels showed no evidence of thermal or cavitation injury, occlusive distal embolization, or perforation. CONCLUSIONS: Our findings in this experimental canine model suggest that ultrasound clot dissolution has the potential to be an effective and safe alternative to current treatment modalities for peripheral arterial thrombosis.Keywords
This publication has 23 references indexed in Scilit:
- Angiography, angioscopy, and ultrasound imaging before and after percutaneous balloon angioplastyAmerican Heart Journal, 1990
- Ultrasonic clot disruption: An in vitro studyAmerican Heart Journal, 1990
- Experimental ultrasonic angioplasty: Disruption of atherosclerotic plaques and thrombi in vitro and arterial recanalization in vivoJACC, 1990
- In vivo ultrasound arterial recanalization of atherosclerotic total occlusionsJACC, 1990
- Combined mechanical and chemical thrombolysis in an experimental animal model: Evaluation by angiography and angioscopyAmerican Heart Journal, 1990
- The use of tissue-type plasminogen activator for acute myocardial infarction in the elderly: Results from thrombolysis in myocardial infarction phase I, open label studies and the thrombolysis in myocardial infarction phase II pilot studyJACC, 1989
- Rotational thrombectomy in acute canine coronary thrombosisInternational Journal of Cardiology, 1989
- ANGIOSCOPY AND LASERS IN CARDIOVASCULAR SURGERY: CURRENT APPLICATIONS AND FUTURE PROSPECTSAnz Journal of Surgery, 1988
- Mortality and morbidity rates of patients older and younger than 75 years with acute myocardial infarction treated with intravenous streptokinaseThe American Journal of Cardiology, 1987
- Arterial Injuries Secondary to the Use of the Fogarty CatheterAnnals of Surgery, 1970