Abstract
To find a better method to suppress cavitation, a microchannel design connecting the internal low‐pressure area with the outside is proposed for the first time in this paper; the method was adopted to replenish fluid in the interior of the low‐pressure area to inhibit cavitation. Through numerical simulation, it is found that the size and position of microchannel have a certain influence on the cavitation inhibition. The results show that the generation and development of cavitation, under the same working conditions, can be effectively restrained by adopting appropriate microchannel (x = 0.05 c, d = 6 cm). Compared with the original hydrofoil, the scale of cavitation is reduced by nearly 50%, and its turbulent kinetic energy remains unchanged. Therefore, it is considered that microchannel technology, as a new means of cavitation suppression, is of great significance to other types of fluid machinery.
Funding Information
  • National Natural Science Foundation of China (51579118)
  • Ministry of Industry and Information Technology of the People's Republic of China (360)
  • Nantong University (19R86)