Reinforcement of the Flexor Tendon Repair Using Human Amniotic Membrane
Authors:
Open Access
- 2 September 2016
- journal article
- Published by MDPI AG in Journal of the American Podiatric Medical Association
- Vol. 106 (5) , 319-322
Abstract
Background: Human amniotic membrane is used to prevent peritendinous adhesions after tendon injuries. This study compares the mechanical properties of modified Kessler repairs and modified Kessler repairs strengthened using multiple layers of human amniotic membrane. Methods: Twenty flexor digitorum profundus tendons of sheep forelimbs were sutured by the two-strand modified Kessler technique (group A) and by the two-strand modified Kessler repair reinforced with multiple layers of human amniotic membrane (group B). To assess the mechanical performance of the repairs, tendons were subjected to a linear noncyclic load-to-failure test using a material testing machine. Outcome measures included ultimate forces and the mode of failure. Results: The mean ± SD value of the failure strength was 34.6 ± 1.64 N for group A and 50.6 ± 5.60 N for group B. The reinforced repair provided a significantly higher ultimate load compared with the nonreinforced group (P < .001). All of the specimens failed due to suture breakage at the repair site. Conclusions: The results of this study show that the modified Kessler repair can be reinforced effectively with human amniotic membrane.Keywords
This publication has 23 references indexed in Scilit:
- Optimum surgical suture material and methods to obtain high tensile strength at knots: problems of conventional knots and the reinforcement effect of adhesive agentJournal of Orthopaedic Science, 2006
- The use of amniotic membrane in flexor tendon repair: an experimental modelArchives of orthopaedic and trauma surgery, 2002
- Aggressive active mobilization following zone II flexor tendon repair using a two-strand heavy-gauge locking loop techniqueJournal of Orthopaedic Science, 2002
- Comparison of Postoperative Early Active Mobilization and Immobilization in Vivo Utilising a Four-Strand Flexor Tendon RepairJournal of Hand Surgery (European Volume), 2001
- Early Active Motion and Weightbearing After Cross-Stitch Achilles Tendon RepairThe American Journal of Sports Medicine, 1998
- The effects of multiple-strand suture methods on the strength and excusion of repaired intrasynovial flexor tendons: A biomechanical study in dogsThe Journal of Hand Surgery, 1998
- Differences between locking loops and grasping loops: Effects on 2-strand core sutureThe Journal of Hand Surgery, 1997
- Effect of suture knot location on tensile strength after flexor tendon repairThe Journal of Hand Surgery, 1996
- Flexor tendon repairJournal of Orthopaedic Research, 1986
- The Influence of Protected Passive Mobilization on the Healing of Flexor Tendons: A Biochemical and Microangiography StudyHand, 1981