Current Only-Based Fault Diagnosis Method for Industrial Robot Control Cables
Open Access
Abstract
With the growth of factory automation, deep learning-based methods have become popular diagnostic tools because they can extract features automatically and diagnose faults under various fault conditions. Among these methods, a novelty detection approach is useful if the fault dataset is imbalanced and impossible reproduce perfectly in a laboratory. This study proposes a novelty detection-based soft fault-diagnosis method for control cables using only currents flowing through the cables. The proposed algorithm uses three-phase currents to calculate the sum and ratios of currents, which are used as inputs to the diagnosis network to detect novelties caused by soft faults. Autoencoder architecture is adopted to detect novelties and calculate anomaly scores for the inputs. Applying a moving average filter to anomaly scores, a threshold is defined, by which soft faults can be properly diagnosed under environmental disturbances. The proposed method is evaluated in 11 fault scenarios. The datasets for each scenario are collected when an industrial robot is working. To induce soft fault conditions, the conductor and its insulator in the cable are damaged gradually according to the scenarios. Experiments demonstrate that the proposed method accurately diagnoses soft faults under various operating conditions and degrees of fault severity.Keywords
Funding Information
- Technology Development Program to Solve Climate Changes through the National Research Foundation of Korea (NRF) funded by the Ministry of Science (ICT (2021M1A2A2043894))
This publication has 25 references indexed in Scilit:
- A Method of Fault Localization Within the Blind Spot Using the Hybridization Between TDR and Wavelet TransformIEEE Sensors Journal, 2020
- Anomalous Example Detection in Deep Learning: A SurveyIEEE Access, 2020
- Industrial Applications of Cable Diagnostics and Monitoring Cables via Time–Frequency Domain ReflectometryIEEE Sensors Journal, 2020
- Equivalent circuit and calculation of unbalanced power in three‐wire three‐phase linear networksIET Generation, Transmission & Distribution, 2018
- A review of novelty detectionSignal Processing, 2014
- A New Algorithm for Wire Fault Location Using Time-Domain ReflectometryIEEE Sensors Journal, 2013
- Diagnosis on MV XLPE power cable by using frequency variance leakage current analysis2008
- Kernel PCA for novelty detectionPattern Recognition, 2007
- The invisible fray: a critical analysis of the use of reflectometry for fray locationIEEE Sensors Journal, 2006
- Understanding receiver operating characteristic (ROC) curvesCanadian Journal of Emergency Medicine, 2006