Application of Piezo-Based Measuring System for Evaluation of Nucleic Acid-Based Drugs Influencing the Coagulation
Authors:
- Silju-John KunnakattuSKSilju-John Kunnakattu
- Ludmilla HannLHLudmilla Hann
- Julia KurzJKJulia Kurz
- Hanna HaagHHHanna Haag
- Stefan FennrichSFStefan Fennrich
- Nicole RauchNRNicole Rauch
- Christian SchlensakCSChristian Schlensak
- Hans-Peter WendelHWHans-Peter Wendel
- Sandra StoppelkampSSSandra Stoppelkamp
- Meltem Avci-AdaliMeltem Avci-Adali
Open Access
Abstract
During open-heart surgery, the status of hemostasis has to be constantly monitored to quickly and reliably detect bleeding or coagulation disorders. In this study, a novel optimized piezo-based measuring system (PIEZ) for rheological monitoring of hemostasis was established. The applicability of the PIEZ for the evaluation of nucleic acid-based drugs influencing coagulation was analyzed. Thrombin aptamers such as NU172 might be used during extracorporeal circulation (ECC) in combination with a reduced heparin concentration or for patients with heparin-induced thrombocytopenia (HIT). Therefore, the effect of the coagulation inhibiting thrombin aptamer NU172 and the abrogation by its complementary antidote sequence (AD) were investigated by this rheological PIEZ system. After the addition of different NU172 concentrations, the coagulation of fresh human blood was analyzed under static conditions and using an in vitro rotation model under dynamic conditions (simulating ECC). The clotting times (CTs) detected by PIEZ were compared to those obtained with a medical reference device, a ball coagulometer. Additionally, after the circulation of blood samples for 30 min at 37 °C, blood cell numbers, thrombin markers (thrombin-antithrombin III (TAT) and fibrinopeptide A (FPA)) and a platelet activation marker (β-thromboglobulin (β-TG)) were analyzed by enzyme-linked immunosorbent assays (ELISAs). The increase of NU172 concentration resulted in prolonged CTs, which were comparable between the reference ball coagulometer and the PIEZ, demonstrating the reliability of the new measuring system. Moreover, by looking at the slope of the linear regression of the viscous and elastic components, PIEZ also could provide information on the kinetics of the coagulation reaction. The shear viscosity at the end of the measurements (after 300 s) was indicative of clot firmness. Furthermore, the PIEZ was able to detect the abrogation of coagulation inhibition after the equimolar addition of NU172 aptamer´s AD. The obtained results showed that the established PIEZ is capable to dynamically measure the hemostasis status in whole blood and can be applied to analyze nucleic acid-based drugs influencing the coagulation.Keywords
Funding Information
- Bundesministerium für Wirtschaft und Energie (KF2589406FR2)
This publication has 35 references indexed in Scilit:
- Free oscillation rheometry monitoring of haemodilution and hypothermia and correction with fibrinogen and factor XIII concentratesScandinavian Journal of Trauma, Resuscitation and Emergency Medicine, 2013
- Potent Anticoagulant Aptamer Directed against Factor IXa Blocks Macromolecular Substrate InteractionJournal of Biological Chemistry, 2012
- A high affinity, antidote‐controllable prothrombin and thrombin‐binding RNA aptamer inhibits thrombin generation and thrombin activityJournal of Thrombosis and Haemostasis, 2012
- Principles and Practice of Thromboelastography in Clinical Coagulation Management and Transfusion PracticeTransfusion Medicine Reviews, 2012
- Red blood cell rheology using single controlled laser-induced cavitation bubblesLab on a Chip, 2010
- Impact of fibrinogen concentration in severely ill patients on mechanical properties of whole blood clotsBlood Coagulation & Fibrinolysis, 2008
- Effects of Cardiac Surgery on HemostasisTransfusion Medicine Reviews, 2006
- Characterization of the viscoelastic behavior of complex fluids using the piezoelastic axial vibratorJournal of Rheology, 2005
- RNA aptamers as reversible antagonists of coagulation factor IXaNature, 2002
- Measurement of blood and plasma coagulation time using free oscillating rheometryScandinavian Journal of Clinical and Laboratory Investigation, 2002