Validity of Woven EndoBridge sizing based on the device-to-aneurysm volume ratio
- 14 November 2024
- journal article
- research article
- Published by SAGE Publications in Interventional Neuroradiology
- Vol. 32 (5) , 2586-2594
Abstract
Background: The Woven EndoBridge (WEB) is a treatment modality available for the treatment of intracranial aneurysms, specifically beneficial in wide-necked bifurcation aneurysms. Conventional sizing methods rely on the manipulation of aneurysm width and height measurements. This results in frequent need for re-sizing after initial WEB insertion attempts. Previous studies have suggested that volume-based sizing may decrease this rate. Methods: We conducted a multicenter retrospective cohort study in three complex vascular centers in the United States from 1 January 2020 to 30 June 2023. All patients who underwent attempted aneurysmal WEB embolization were included. Using three-dimensional angiogram reconstructions, we measured the aneurysm volume. We calculated the WEB volume and measured the WEB-aneurysm volume (WAVe) ratio. The primary outcome was whether a WEB required re-sizing. Results: A total of 133 cases were identified, 114 correctly sized and 19 incorrectly sized. Twelve patients (9.0%) required additional stent placement during WEB insertion. One patient (0.8%) had WEB abandonment. There were no differences in demographic or baseline characteristics between the size/re-sizing cohorts aside from aneurysm location (“other” and basilar locations increased the rate of re-sizing). The median WAVe ratio in our appropriately sized cohort was 0.997 (interquartile range (IQR) 0.826, 1.30) versus 1.14 in our re-sizing cohort (IQR 0.734, 1.51; p = 0.728). Using logistic regression, we identified a WAVe ratio ranging from 0.76 to 1.24 yielding > 80% probability of a successful sizing with 95% confidence. Conclusions: Incorporating volume-based measurements in aneurysm embolization with WEBs may improve rates of re-sizing but has an unclear effect on aneurysm occlusion. A WAVe ratio of 0.76–1.24 provides the greatest probability of appropriate initial WEB sizing.Keywords
This publication has 16 references indexed in Scilit:
- Neck apposition is a key factor for aneurysm occlusion after Woven EndoBridge device embolizationJournal of NeuroInterventional Surgery, 2024
- Decision-making tree for optimal Woven EndoBridge device sizing with ideal Woven EndoBridge-aneurysm volume (iWAVe) ratioJournal of Clinical Neuroscience, 2023
- Treatment of Wide-Necked Cerebral Aneurysms Using the WEB Device Including Flow Alteration Assessment With Color-Coded Imaging: A Single Center ExperienceWorld Neurosurgery: X, 2022
- Determinants of cerebral aneurysm occlusion after embolization with the WEB device: a single-institution series of 215 cases with angiographic follow-upJournal of NeuroInterventional Surgery, 2022
- A single centre retrospective analysis of short- and medium-term outcomes using the Woven EndoBridge (WEB) device and identification of the device-to-aneurysm volume ratio as a potential predictor of aneurysm occlusion statusInterventional Neuroradiology, 2022
- Volume-based sizing of the Woven EndoBridge (WEB) device: A preliminary assessment of a novel method for device size selectionInterventional Neuroradiology, 2021
- Comparison of Woven EndoBridge device sizing with conventional measurements and virtual simulation using the Sim&Size software: a multicenter experienceJournal of NeuroInterventional Surgery, 2020
- How to WEB: a practical review of methodology for the use of the Woven EndoBridgeJournal of NeuroInterventional Surgery, 2020
- The Woven Endobridge Device for Treatment of Intracranial Aneurysms: A Systematic ReviewWorld Neurosurgery, 2017
- Occlusion assessment of intracranial aneurysms treated with the WEB deviceNeuroradiology, 2016