The T-pod is as stable as supraacetabular fixation using 1 or 2 Schanz screws in partially unstable pelvic fractures: a biomechanical study
Open Access
- 18 July 2020
- journal article
- research article
- Published by Springer Nature in European Journal of Medical Research
- Vol. 25 (1) , 1-7
Abstract
Introduction: Unstable fractures of the pelvis remain the predominant cause of severe hemorrhage, shock and early death in severely injured patients. The use of pelvic binders has become increasingly popular, particularly in the preclinical setting. There is currently insufficient evidence available about the stability of the pelvic binder versus supraacetabular fixation using 1 or 2 Schanz screws. We aimed to analyze the stability of the pelvic binder and supraacetabular fixateurs using either 1 or 2 Schanz screws in a cadaver model of an induced pelvic B-type fracture. Materials and methods: The study was undertaken in 7 human fresh-frozen cadaveric pelvises with induced AO-type B fractures. Three stabilization techniques were compared: T-POD (pelvic bandage), supraacetabular external fixator with 1 pin on each side and external fixator with 2 pins on each side. Stability and stiffness were analyzed in a biomechanical testing machine using a 5-step protocol with static and dynamic loading, dislocation data were retrieved by ultrasound sensors at the fracture sites. Results: No significant differences in fracture fragment displacement were detected when using either the T-POD, a 1-pin external fixator or a 2-pin external fixator (P > 0.05). The average difference in displacement between the three methods was < 1 mm. Conclusions: Pelvic binders are suitable for reduction of pelvic B-type fractures. They provide stability comparable to that of supraacetabular fixators, independently of whether 1 or 2 Schanz screws per side are used. Pelvic binders provide sufficient biomechanical stability for transferring patients without the need to first replace them with surgically applied external fixators. However, soft tissue irritation has to be taken into consideration and prolonged wear should be avoided. Level of evidence: Level IIIKeywords
Funding Information
- FöFoLe-Grant Reg.-Nr. 935 (935)
This publication has 20 references indexed in Scilit:
- Retroperitoneal packing or angioembolization for haemorrhage control of pelvic fractures—Quasi-randomized clinical trial of 56 haemodynamically unstable patients with Injury Severity Score ≥33Injury, 2016
- When do anterior external or internal fixators provide additional stability in an unstable (Tile C) pelvic fracture? A biomechanical studyEuropean Journal of Trauma and Emergency Surgery, 2014
- Comparison of circumferential pelvic sheeting versus the T-POD on unstable pelvic injuries: A cadaveric study of stabilityInjury, 2013
- Does Application Position of the T-POD Affect Stability of Pelvic Fractures?Journal of Orthopaedic Trauma, 2013
- Comparison of external fixation versus the trauma pelvic orthotic device on unstable pelvic injuriesJournal of Trauma and Acute Care Surgery, 2012
- Effectiveness and complications of pelvic circumferential compression devices in patients with unstable pelvic fractures: A systematic review of literatureInjury, 2009
- Pressure characteristics of pelvic bindersInjury, 2007
- Skin Breakdown Following Circumferential Pelvic Antishock SheetingJournal of Orthopaedic Trauma, 2005
- Der einfache supraazetabuläre Fixateur externe für die Behandlung von BeckenfrakturenOperative Orthopädie und Traumatologie, 2005
- Pelvic Fracture Classification1988