Abstract
Abstract:Accurate imaging of impedance changes in the brain with EIT using scalp electrodes ideally requires an algorithm designed for a 3D hemispherical object that is capable of imaging through the skull. A 2D algorithm is presented, intended as the first step towards a full 3D version. It is based on a sensitivity matrix approach and allows images to be reconstructed from any electrode positions. Its performance was assessed using a 2D circular tank with a simulated skull. The findings suggested the following: if polar current drive was used with no explicit skull compensation, a feature in the image would be placed 25% closer to the center and would be around one‐third the amplitude of an identical perturbation in a homogeneous medium.Keywords
This publication has 14 references indexed in Scilit:
- Improvement of the positional accuracy of EIT images of the head using a Lagrange multiplier reconstruction algorithm with diametric excitationPhysiological Measurement, 1996
- Three-dimensional image reconstruction for electrical impedance tomographyPhysiological Measurement, 1996
- An interleaved drive electrical impedance tomography image reconstruction algorithmPhysiological Measurement, 1996
- Imaging of physiologically evoked responses by electrical impedance tomography with cortical electrodes in the anaesthetized rabbitPhysiological Measurement, 1996
- 3D reconstruction in electrical impedance imaging using a direct sensitivity matrix approachPhysiological Measurement, 1995
- Experimental validation of a novel reconstruction algorithm for electrical impedance tomography based on backprojection of Lagrange multipliersPhysiological Measurement, 1995
- Design considerations and performance of a prototype system for imaging neuronal depolarization in the brain using 'direct current' electrical resistance tomographyPhysiological Measurement, 1995
- A sensitivity region reconstruction algorithm using adjacent drive current injection strategyClinical Physics and Physiological Measurement, 1992
- The effect of the skull of low-birthweight neonates on applied potential tomography imaging of centralised resistivity changesClinical Physics and Physiological Measurement, 1988
- Fast reconstruction of resistance imagesClinical Physics and Physiological Measurement, 1987