Disposable screen-printed sensors for the electrochemical detection of TNT and DNT
- 7 November 2012
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 138 (1) , 346-352
Abstract
Due to the heightened level of national security currently prevalent due to the possibility of terrorist incidents, highly portable, miniaturised and sensitive monitoring devices for trace levels of injurious materials, such as explosives are now of the upmost importance. One method that offers a possible route for the development of a detection system for such species is via an electrochemical regime, coupled to the use of disposable sensor technology. Within this study, the use of carbon screen-printed sensors for the detection and analysis of the classical explosive trinitrotoluene (TNT) and the related dinitrotoluene (DNT) is described, with the eventual objective to develop an inexpensive, accurate and sensitive detection system for trace quantities of explosives in field settings. Commercially available screen-printed carbon sensors have been used as the base platform for this investigation and the electrochemistry of both TNT and DNT studied at these surfaces. Two reductive peaks and one oxidative peak were observed for both analytes. The best linear fits and sensitivities were obtained using the reductive peak at −0.72 V vs. Ag/AgCl. A linear range from 1 to 200 μM could be obtained for TNT and DNT in pH 7.0 phosphate buffer with limits of detection as low as 0.4 μM (TNT) and 0.7 μM (DNT). A second system which utilised the addition of the enzyme, nitroreductase, and the coenzyme, NADPH, into the solution matrix prior to electrochemical interrogations with screen-printed carbon electrodes was found to increase the resulting signal magnitude at the oxidation peak at +0.3 V, improving the performance of the sensor at these values.Keywords
This publication has 20 references indexed in Scilit:
- Current trends in explosive detection techniquesTalanta, 2012
- Electrochemical detection of ultratrace nitroaromatic explosives using ordered mesoporous carbonAnalytica Chimica Acta, 2011
- Integrated explosive preconcentrator and electrochemical detection system for 2,4,6-trinitrotoluene (TNT) vaporAnalytica Chimica Acta, 2010
- {MSU/PDDA}n LBL assembled modified sensor for electrochemical detection of ultratrace explosive nitroaromatic compoundsElectrochemistry Communications, 2007
- Electrochemical Sensing of ExplosivesElectroanalysis, 2007
- Disposable Electrochemical Sensor for Determination of Nitroaromatic Compounds by a Single-Run ApproachAnalytical Chemistry, 2006
- Rapid voltammetric determination of nitroaromatic explosives at electrochemically activated carbon-fibre electrodesAnalytical and Bioanalytical Chemistry, 2005
- Screen-printed voltammetric sensor for TNTTalanta, 1998
- Continuous-flow immunosensor for detection of explosivesAnalytical Chemistry, 1993
- Determination of nitro aromatic, nitramine, and nitrate ester explosive compounds in explosive mixtures and gunshot residue by liquid chromatography and reductive electrochemical detectionAnalytica Chimica Acta, 1981