Precision in Practice: Inter- and Intra-rater Reliability of Linear Measurements and Tumor Growth in Vestibular Schwannoma
Open Access
- 12 June 2025
- journal article
- research article
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 46 (7) , e278-e284
Abstract
Objective: The aim of this study is to compare and assess the inter- and intra-rater reliability of various linear measurement techniques for vestibular schwannomas (VS) and their impact on determining tumor growth in a multidisciplinary multicenter setting. Methods: Six experts (neurosurgeons, otorhinolaryngologists, and radiologists) involved in VS management, from two tertiary referral centers, measured linear extrameatal VS tumor size parallel and perpendicular to the petrous ridge, and as maximum axial and maximum coronal diameter. Inter- and intra-rater reliability were evaluated using the intraclass correlation coefficient (ICC). The repeatability coefficient was computed for each measurement direction. Fleiss' kappa was used to determine the degree of agreement on tumor growth. Results: Reliability between raters was significantly excellent (ICC >0.9) across all measurement directions, with the highest ICC observed for measurements parallel to the petrous ridge (ICC, 0.974; 95% CI, 0.957–0.986). Good or excellent reliability was achieved in 95.8% of all intra-rater measurements, with predominantly higher ICC scores for measurements in the coronal plane. Fleiss' kappa for interrater variability of determining tumor growth was highest and substantial for measurements parallel to the petrous ridge 0.672 (95% CI, 0.546–0.799). Conclusion: Linear measurements of VS parallel to the petrous ridge yield excellent interrater reliability and the most favorable repeatability coefficient. Good to excellent intra-rater reliability across all measurement directions was observed. The most accurately defined tumor growth was obtained comparing measurements parallel to the petrous ridge. We recommend measurements parallel to the petrous ridge as the standard linear method for evaluating VS and growth.Keywords
This publication has 25 references indexed in Scilit:
- Defining tumor growth in vestibular schwannomas: a volumetric inter-observer variability study in contrast-enhanced T1-weighted MRINeuroradiology, 2024
- Upfront Radiosurgery vs a Wait-and-Scan Approach for Small- or Medium-Sized Vestibular SchwannomaJAMA, 2023
- Subclassification of the Koos grade 2 vestibular schwannoma into 2a and 2b for individualized patient care: A validity and reliability studyEuropean Journal of Radiology, 2023
- Volumetric measurement of intracranial meningiomas: a comparison between linear, planimetric, and machine learning with multiparametric voxel-based morphometry methodsJournal of Neuro-Oncology, 2022
- Hannover Classification of Vestibular Schwannomas: A Reliability StudyWorld Neurosurgery, 2022
- Evaluating vestibular schwannoma size and volume on magnetic resonance imaging: An inter- and intra-rater agreement studyClinical Neurology and Neurosurgery, 2016
- A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability ResearchJournal of Chiropractic Medicine, 2016
- Analysis of vestibular schwannoma size: A literature review on consistency with measurement techniquesClinical Neurology and Neurosurgery, 2015
- Follow-up assessment of vestibular schwannomas: volume quantification versus two-dimensional measurementsNeuroradiology, 2009
- Committee on Hearing and Equilibrium guidelines for the evaluation of hearing preservation in acoustic neuroma (vestibular schwannoma)∗Otolaryngology–Head and Neck Surgery, 1995