Relative survival of Bacillus subtilis spores loaded on filtering facepiece respirators after five decontamination methods
Authors:
Open Access
- 31 May 2018
- journal article
- research article
- Published by Wiley in Indoor Air
- Vol. 28 (5) , 754-762
Abstract
This study determines the relative survival (RS) of Bacillus subtilis spores loaded on an N95 filtering facepiece respirator (FFR) after decontamination by five methods under worst-case conditions. Relative survival was obtained by testing after decontamination and after storing the FFRs at 37°C and 95% relative humidity for 24 hours. The decontamination methods involved ethanol, bleach, ultraviolet irradiation (UVA 365 nm, UVC 254 nm), an autoclave, and a traditional electric rice cooker (TERC) that was made in Taiwan. Without decontamination, 59 ± 8% of the loaded spores survived for 24 hours. When 70% ethanol was added to the N95 FFR at a packing density of 0.23, the RS was 73 ± 5% initially and decayed to 22 ± 8% in 24 hours. Relative survival remained above 20% after 20 minutes of UVA irradiation. The other four decontamination measures achieved 99%-100% biocidal efficacy, as measured immediately after the methods were applied to the test FFRs. Relative survival is a useful parameter for measuring sterilization or degree of disinfection. Bleach, UVC, an autoclave, and a TERC provide better biocidal efficacy than ethanol and UVA. Not only a higher filter quality but also a lower value of RS produced the most decontaminated FFR.Keywords
Funding Information
- Ministry of Science and Technology, Taiwan
- Institute of Labor, Occupational Safety and Health, Ministry of Labor, Taiwan
This publication has 22 references indexed in Scilit:
- Influenza Virus Aerosols in Human Exhaled Breath: Particle Size, Culturability, and Effect of Surgical MasksPLOS Pathogens, 2013
- Effectiveness of Three Decontamination Treatments against Influenza Virus Applied to Filtering Facepiece RespiratorsAnnals of Occupational Hygiene, 2011
- A method to determine the available UV-C dose for the decontamination of filtering facepiece respiratorsJournal of Applied Microbiology, 2011
- Evaluation of Five Decontamination Methods for Filtering Facepiece RespiratorsAnnals of Occupational Hygiene, 2009
- Survival of Bacteria on Respirator FiltersAerosol Science and Technology, 1999
- Evaluation of Microbial Samplers for Bacterial MicroorganismsAerosol Science and Technology, 1999
- Framework for Evaluating Measures to Control Nosocomial Tuberculosis TransmissionIndoor Air, 1998
- The Effects of Particle Charge on the Performance of a Filtering FacepieceAIHA Journal, 1998
- The Effect of Sampling Time and Flow Rates on the Bioefficiency of Three Fungal Spore Sampling MethodsAerosol Science and Technology, 1998
- Comparative sporicidal effect of liquid chemical germicides on three medical devices contaminated with spores of Bacillus subtilisAmerican Journal of Infection Control, 1996