Fault location in multi-terminal HVDC networks based on Electromagnetic Time Reversal with limited time reversal window
- 1 August 2014
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Abstract
This paper aims at proving the application of the fault location method based on the Electromagnetic Time Reversal (EMTR) to multi-terminal HVDC (MTDC) networks. In particular, the paper integrates the EMTR fault location technique with the protection scheme recently proposed within the EU project TWENTIES. Further, in view of the peculiarity of the fast protection schemes required by HVDC applications, the paper discusses the performances of the EMTR-based fault location technique by using limited time-windows over which the fault-generated electromagnetic transients are time-reversed. The paper also discusses the advantage of the EMTR fault location related to the use of a single observation point to the case of MTDC grids. Indeed, such a peculiarity may represent a major advantage avoiding necessary time synchronization between the MTDC-fault recording stations and might represents, also, a backup protection system. The performances of the proposed method are validated by numerical simulations obtained using the EMTP-RV simulation environment where electromagnetic fault-transients are reproduced with reference to the MTDC benchmark network of the project TWENTIES.Keywords
This publication has 23 references indexed in Scilit:
- Time reversal of electromagnetic fields and its application to lightning location2013
- Protection system for meshed HVDC network using superconducting fault current limiters2013
- On the use of electromagnetic time reversal to locate faults in series-compensated transmission lines2013
- Protection strategy for undersea MTDC grids2013
- An Efficient Method Based on the Electromagnetic Time Reversal to Locate Faults in Power NetworksIEEE Transactions on Power Delivery, 2013
- Application of the time reversal of electromagnetic fields to locate lightning dischargesAtmospheric Research, 2012
- An Electronic Circuit System for Time-Reversal of Ultra-Wideband Short Impulses Based on Frequency-Domain ApproachIEEE Transactions on Microwave Theory and Techniques, 2009
- Electromagnetic time-reversal imaging of a target in a cluttered environmentIEEE Transactions on Antennas and Propagation, 2005
- Time Reversal of Electromagnetic WavesPhysical Review Letters, 2004
- Time-reversal of ultrasonic fields. III. Theory of the closed time-reversal cavityIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1992