A Mock Circulatory System Incorporating a Compliant 3D‐Printed Anatomical Model to Investigate Pulmonary Hemodynamics
- 7 December 2016
- journal article
- research article
- Published by Wiley in Artificial Organs
- Vol. 41 (7) , 637-646
Abstract
A realistic mock circulatory system (MCS) could be a valuable in vitro testbed to study human circulatory hemodynamics. The objective of this study was to design a MCS replicating the pulmonary arterial circulation, incorporating an anatomically representative arterial model suitable for testing clinically relevant scenarios. A second objective of the study was to ensure the system's compatibility with magnetic resonance imaging (MRI) for additional measurements. A latex pulmonary arterial model with two generations of bifurcations was manufactured starting from a 3D‐printed mold reconstructed from patient data. The model was incorporated into a MCS for in vitro hydrodynamic measurements. The setup was tested under physiological pulsatile flow conditions and results were evaluated using wave intensity analysis (WIA) to investigate waves traveling in the arterial system. Increased pulmonary vascular resistance (IPVR) was simulated as an example of one pathological scenario. Flow split between right and left pulmonary artery was found to be realistic (54 and 46%, respectively). No substantial difference in pressure waveform was observed throughout the various generations of bifurcations. Based on WIA, three main waves were identified in the main pulmonary artery (MPA), that is, forward compression wave, backward compression wave, and forward expansion wave. For IPVR, a rise in mean pressure was recorded in the MPA, within the clinical range of pulmonary arterial hypertension. The feasibility of using the MCS in the MRI scanner was demonstrated with the MCS running 2 h consecutively while acquiring preliminary MRI data. This study shows the development and verification of a pulmonary MCS, including an anatomically correct, compliant latex phantom. The setup can be useful to explore a wide range of hemodynamic questions, including the development of patient‐ and pathology‐specific models, considering the ease and low cost of producing rapid prototyping molds, and the versatility of the setup for invasive and noninvasive (i.e., MRI) measurements.Keywords
Funding Information
- National Institute for Health Research
- Heart Research UK
- Royal Academy of Engineering
This publication has 34 references indexed in Scilit:
- Rapid prototyping compliant arterial phantoms for in-vitro studies and device testingJournal of Cardiovascular Magnetic Resonance, 2013
- A non-invasive clinical application of wave intensity analysis based on ultrahigh temporal resolution phase-contrast cardiovascular magnetic resonanceJournal of Cardiovascular Magnetic Resonance, 2012
- In vitro simulation and validation of the circulation with congenital heart defectsProgress in Pediatric Cardiology, 2010
- A Mock Circulatory System With Physiological Distribution of Terminal Resistance and Compliance: Application for Testing the Intra‐Aortic Balloon PumpArtificial Organs, 2010
- Experimental Setup to Evaluate the Performance of Percutaneous Pulmonary Valved Stent in Different Outflow Tract MorphologiesArtificial Organs, 2009
- Proximal pulmonary artery blood flow characteristics in healthy subjects measured in an upright posture using MRI: The effects of exercise and ageJournal of Magnetic Resonance Imaging, 2005
- Determination of wave speed and wave separation in the arteriesJournal of Biomechanics, 2001
- Development of mock circulation models for the assessment of counterpulsation systemsCardiovascular Research, 1991
- Forward and Backward Running Waves in the Arteries: Analysis Using the Method of CharacteristicsJournal of Biomechanical Engineering, 1990
- The “Effective” Pulmonary Collateral Blood Flow in Man1Journal of Clinical Investigation, 1958