Loop Heat Pipes - Recent Developments, Test Results and Applications
Authors:
- 2 August 1999
- conference paper
- Published by SAE International in SAE International Journal of Advances and Current Practices in Mobility
- Vol. 1
Abstract
Loop heat pipes are one of the most promising modifications of two-phase heat-transfer devices with capillary pumping. Owing to their versatility these devices have filled a wide niche between ordinary heat pipes and CPLs.The paper presents the results of development and investigations of loop heat pipes carried out at the Institute of Thermophysics in the last five years.Keywords
This publication has 4 references indexed in Scilit:
- Thermal Performance and Operational Characteristics of Loop Heat Pipe (NRL LHP)SAE International Journal of Advances and Current Practices in Mobility, 1998
- Loop Heat Pipes - Their Performance and PotentialSAE International Journal of Advances and Current Practices in Mobility, 1994
- Design of heat pipe cooled laser mirrors with an inverted meniscus evaporator wick1980
- Some results of investigations of low-temperature heat pipes, working against gravityJournal of Engineering Physics and Thermophysics, 1976