Securing Jugular Central Venous Catheters With Dressings Fixed to a Liquid Adhesive to Prevent Dressing Failure in Intensive Care Patients (the STICKY Trial): A Randomized Controlled Trial
Authors:
- Nicole Rn MarshNMNicole Rn Marsh
- Catherine RN O’BrienCOCatherine RN O’Brien
- Emily N. RN LarsenELEmily N. RN Larsen
- Evan Rn AlexandrouEAEvan Rn Alexandrou
- Robert S. WareRobert S. Ware
- India RN PearseIPIndia RN Pearse
- Fiona Rn CoyerFCFiona Rn Coyer
- Maharshi S. Mbiostat PatelMPMaharshi S. Mbiostat Patel
- Ruth H. Rn RoyleRRRuth H. Rn Royle
- Claire M. Rn RickardCRClaire M. Rn Rickard
- Kellie RN SosnowskiKSKellie RN Sosnowski
- Patrick N. A. Mbbs HarrisPHPatrick N. A. Mbbs Harris
Open Access
- 21 February 2025
- journal article
- research article
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 53 (2) , e282-e293
Abstract
OBJECTIVES: Central venous catheters (CVCs) are vital for treating ICU patients. However, up to a quarter of CVCs fail from mechanical or infective complications. Poor securement of CVCs to the skin contributes to catheter failure, particularly CVCs placed in the jugular vein, which are highly vulnerable to pullout forces. This study evaluated the effectiveness of medical liquid adhesive (MLA) for improving jugular CVC dressing adhesion. DESIGN: Multisite parallel group, superiority, randomized controlled trial. SETTING: Four metropolitan Australian ICUs. PATIENTS: Eligible patients were 18 years old or older, within 12 hours of jugular CVC insertion, expected to need the CVC for greater than or equal to 72 hours, and remain in ICU for greater than or equal to 24 hours. INTERVENTIONS: Patients were randomly allocated (stratified by hospital and gender) to standard CVC dressings with the application of MLA to skin under the dressing border (intervention) or standard care CVC dressings (control). MEASUREMENTS AND MAIN RESULTS: The primary endpoint was dressing failure within 7 days due to lifting edges. Secondary outcomes included the total number of dressing changes, skin injury, and CVC failure. In total, 160 participants (82 control; 78 intervention) were enrolled. There were 22 (28%) and 41 (50%) cases of premature dressing failure in the intervention and control groups respectively (odds ratio, 0.39; 95% CI, 0.20–0.76; p = 0.005). The intervention group had fewer dressing changes (incidence rate ratio [IRR], 0.74; 95% CI, 0.55–0.99). Time to dressing failure (log-rank test; p = 0.12) and all-cause CVC failure (IRR, 1.44; 95% CI, 0.36–5.79) did not differ between groups. Three skin injuries occurred: one in the intervention (blister) and two in the control (maceration and skin tear) groups. CONCLUSIONS: MLA is associated with significantly decreased jugular CVC dressing failure and longer dressing dwell, with an acceptable safety profile. MLA should be considered to preserve jugular CVC dressings in ICU.Keywords
Funding Information
- Eloquest Healthcare
This publication has 39 references indexed in Scilit:
- Attributable Cost and Length of Stay for Central Line-Associated Bloodstream InfectionsPediatrics, 2014
- epic3: National Evidence-Based Guidelines for Preventing Healthcare-Associated Infections in NHS Hospitals in EnglandJournal of Hospital Infection, 2014
- Incidence of catheter-related complications in patients with central venous or hemodialysis catheters: a health care claims database analysisBMC Cardiovascular Disorders, 2013
- Allergic contact dermatitis at the epidural catheter site due to Mastisol® liquid skin adhesiveCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2012
- Dressing disruption is a major risk factor for catheter-related infections*Critical Care Medicine, 2012
- Guidelines for the prevention of intravascular catheter-related infectionsAmerican Journal of Infection Control, 2011
- Allergic contact dermatitis from Mastisol mistaken for cellulitisContact Dermatitis, 2007
- Nosocomial Bloodstream Infections in US Hospitals: Analysis of 24,179 Cases from a Prospective Nationwide Surveillance StudyClinical Infectious Diseases, 2004
- Increased Resource Use Associated With Catheter-Related Bloodstream Infection in the Surgical Intensive Care UnitArchives of Surgery, 2001
- The influence of tape type and of skin preparation on the force required to dislodge angiocathetersCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1994