Validation of the SenseWear Armband at high intensity exercise
- 24 October 2010
- journal article
- research article
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 111 (5) , 883-887
Abstract
The SenseWear Armband (SWA) has been shown to be a valid and practical tool to assess energy expenditure during habitual physical activity. However, previous studies have focused on low-to-moderate intensity activities. The purpose of this study was to assess the validity of the SWA during high intensity exercise. Twenty (ten males, ten females) endurance trained subjects, 24.3 (±2.8) years of age, performed three 10-min treadmill runs at 65, 75, and 85% of their VO2max each and also ran outside for 30 min at their preferred speed. Energy expenditure was measured with the SWA (software version 6.1) and a portable indirect calorimetry system (Jaeger Oxycon Mobile®). The SWA showed a ceiling effect around an intensity of ten METs. Since all subjects exceeded that intensity range during the exercise trials, the SWA significantly underestimated energy expenditure at high intensities. The intra-individual correlations between MET values calculated by the SWA and values derived from the Oxycon, however, were significant for all but two subjects (r = 0.390–0.933, mean = 0.66 ± 0.25). While providing accurate results for energy expenditure during low-to-moderate intensity physical activities, the SWA does not provide accurate estimates of energy expenditure at high intensity levels. The threshold for accurate measurements seems to be around an intensity of ten METs.Keywords
This publication has 11 references indexed in Scilit:
- Validation of the SenseWear Pro Armband Algorithms in ChildrenMedicine & Science in Sports & Exercise, 2009
- Accelerometers and pedometers: methodology and clinical applicationCurrent Opinion in Clinical Nutrition and Metabolic Care, 2007
- A new device for measuring resting energy expenditure (REE) in healthy subjectsNutrition, Metabolism and Cardiovascular Diseases, 2007
- Evaluation of a portable device to measure daily energy expenditure in free-living adultsThe American Journal of Clinical Nutrition, 2007
- Validity and Stability of a Computerized Metabolic System with Mixing ChamberInternational Journal of Sports Medicine, 2004
- Comparison of Activity Monitors to Estimate Energy Cost of Treadmill ExerciseMedicine & Science in Sports & Exercise, 2004
- Validity of a Multi-Sensor Armband in Estimating Rest and Exercise Energy ExpenditureMedicine & Science in Sports & Exercise, 2004
- Estimating Human Energy ExpenditureSports Medicine, 2003
- Measurement issues in the assessment of physical activity in children.2000
- Measurement Issues in the Assessment of Physical Activity in ChildrenResearch Quarterly for Exercise and Sport, 2000