CT-based attenuation correction in the calculation of semi-quantitative indices of [18F]FDG uptake in PET
- 20 December 2002
- journal article
- research article
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 30 (3) , 344-353
Abstract
The introduction of combined PET/CT systems has a number of advantages, including the utilisation of CT images for PET attenuation correction (AC). The potential advantage compared with existing methodology is less noisy transmission maps within shorter times of acquisition. The objective of our investigation was to assess the accuracy of CT attenuation correction (CTAC) and to study resulting bias and signal to noise ratio (SNR) in image-derived semi-quantitative uptake indices. A combined PET/CT system (GE Discovery LS) was used. Different size phantoms containing variable density components were used to assess the inherent accuracy of a bilinear transformation in the conversion of CT images to 511 keV attenuation maps. This was followed by a phantom study simulating tumour imaging conditions, with a tumour to background ratio of 5:1. An additional variable was the inclusion of contrast agent at different concentration levels. A CT scan was carried out followed by 5 min emission with 1-h and 3-min transmission frames. Clinical data were acquired in 50 patients, who had a CT scan under normal breathing conditions (CTACnb) or under breath-hold with inspiration (CTACinsp) or expiration (CTACexp), followed by a PET scan of 5 and 3 min per bed position for the emission and transmission scans respectively. Phantom and patient studies were reconstructed using segmented AC (SAC) and CTAC. In addition, measured AC (MAC) was performed for the phantom study using the 1-h transmission frame. Comparing the attenuation coefficients obtained using the CT- and the rod source-based attenuation maps, differences of 3% and avg) between the phantom images reconstructed with MAC and those reconstructed with CTAC and SAC respectively. In the case of CTAC, the difference increased up to 27% with the presence of contrast agent. The presence of metallic implants led to underestimation in the surrounding SUVavg and increasing non-uniformity in the proximity of the implant. The patient study revealed no statistically significant differences in the SUVavg between either CTACnb or CTACexp and SAC-reconstructed images. The larger differences were recorded in the lung. Both the phantom and the patient studies revealed an average increase of ~25% in the SNR for the CTAC-reconstructed emission images compared with the SAC-reconstructed images. In conclusion, CTACnb or CTACexp is a viable alternative to SAC for whole-body studies. With CTAC, careful consideration should be given to interpretation of images and use of SUVs in the presence of oral contrast and in the proximity of metallic implants.Keywords
This publication has 19 references indexed in Scilit:
- PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficientsEuropean Journal of Nuclear Medicine and Molecular Imaging, 2002
- Preoperative Staging of Non–Small-Cell Lung Cancer with Positron-Emission TomographyNew England Journal of Medicine, 2000
- Measurement of clinical and subclinical tumour response using [18F]-fluorodeoxyglucose and positron emission tomography: review and 1999 EORTC recommendationsEuropean Journal of Cancer, 1999
- Attenuation correction for a combined 3D PET/CT scannerMedical Physics, 1998
- DETECT-dual energy transmission estimation CT-for improved attenuation correction in SPECT and PETIEEE Transactions on Nuclear Science, 1998
- Adaptive, segmented attenuation correction for whole-body PET imagingIEEE Transactions on Nuclear Science, 1996
- Iterative deblurring for CT metal artifact reductionIEEE Transactions on Medical Imaging, 1996
- Contribution of PET in the diagnosis of recurrent colorectal cancer: comparison with conventional imagingEuropean Journal of Surgical Oncology, 1995
- Epoxy resin based tissue substitutesBritish Journal of Radiology, 1977
- Book reviewComputed Brain and Orbital Tomography. Technique and Interpretation. By GonzalezCarlos F., GrossmanCharles B., and PalaciosEnrique, pp. xii + 276, 200 figs. (Chichester, John Wiley), £21·76.British Journal of Radiology, 1977