Defects and gallium-contamination during focused ion beam micro machining
Authors:
- L. FreyLFL. Frey
- S. PetersenSPS. Petersen
- M. MizutaniMMM. Mizutani
- M. TakaiMTM. Takai
- H. RysselHRH. Ryssel
- 1 January 2000
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 695-698
Abstract
Low energy focused ion beam (FIB) systems are used for the modification of integrated circuits, the preparation of TEM samples, the processing of structures in the sub -100 nm range, and for failure analysis. Focused gallium ion beams with diameters down to <10 nm (Full Width at Half Maximum) allow high resolution secondary electron surface inspection as well as local removal and deposition of material with high accuracy by physical sputtering or ion induced chemistry. Besides beam diameter and shape, gallium implantation and defect generation limit the application of FIB micro machining towards minimum resolution and sensitive analysis. Even when the desired structural dimensions are achieved, functionality of the sample may be hindered by implanted gallium and introduced defects. In this paper, vertical gallium distribution and lateral contamination for highly focused ion beam applications are investigated. SIMS analysis and Monte Carlo simulation are used for the determination for doses ranging from FIB inspection (1/spl middot/10/sup 14/ cm/sup -2/) to sputter removal at high doses (up to 1/spl middot/10/sup 18/ cm/sup -2/). The measurements revealed surface concentrations of 1/spl middot/10/sup 18/ cm/sup -3/ up to 6/spl middot/10/sup 21/ cm/sup -3/ and deep ranging tails. At doses exceeding 1.10/sup 17/ cm/sup -2/, the surface concentration reaches 6/spl middot/10/sup 21/ cm/sup -3/ and saturates, which is in agreement with simulations. Lateral contamination is determined by gallium background implantation due to inspection before processing and by non scanned neutrals. Defect generation was investigated by TEM. Even for typical FIB inspection at low doses (30 keV, 1/spl middot/10/sup 14/ cm/sup -2/) an amorphous layer is generated with a thickness of 50 nm.Keywords
This publication has 11 references indexed in Scilit:
- Ion beam-treated silicon probes operated in transmission and cross-polarized reflection mode near-infrared scanning near-field optical microscopy (NIR-SNOM)Surface and Interface Analysis, 1999
- A comparison of focused ion beam and electron beam induced deposition processesMicroelectronics Reliability, 1996
- Local material removal by focused ion beam milling and etchingNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1995
- Low-damage specimen preparation technique for transmission electron microscopy using iodine gas-assisted focused ion beam millingJournal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena, 1995
- Focused-ion-beam implantation of Ga in elemental and compound semiconductorsJournal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena, 1995
- Focused ion beam deposition of Pt containing filmsJournal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena, 1992
- Computer simulations of sputteringNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1987
- Integrated circuit repair using focused ion beam millingJournal of Vacuum Science & Technology B, 1986
- Condensation of bombarding gallium ions on a silicon surfaceApplied Physics Letters, 1981
- A Monte Carlo computer program for the transport of energetic ions in amorphous targetsNuclear Instruments and Methods, 1980