Knot security and tensile strength of suture materials
Authors:
- 19 November 2013
- journal article
- Published by Wiley in Veterinary Surgery
- Vol. 43 (1) , 73-79
Abstract
Objective: To evaluate knot security and tensile failure load of suture tied in simple interrupted, beginning continuous, and ending continuous patterns for 11 suture materials commonly used in small animal surgery.Study design: Mechanical study.Methods: For each of 11 suture material types, and 5 knot sizes (2, 3, 4, 5, and 6 throws) 2 surgeons each tied 6 knots (n = 12 for each knot size in 11 suture materials). Three types of patterns were evaluated: a simple interrupted square knot, a square knot beginning a simple continuous pattern, and the knot ending a simple continuous pattern. All knots were incubated in healthy canine donor plasma at 40°C for a minimum of 24 hours. Sutures were evaluated for knot security (knots untied, suture failed by breaking, suture slipped from the clamps, or suture untied before testing) and maximum load carried before knot slippage or knot failure (termed tensile failure load).Results: Significant differences were found in knot security and tensile failure load among suture types. There was no significant difference between the simple interrupted knots and the knots at the beginning of a simple continuous pattern; however, both were significantly less likely to fail than the knots tied at the end of a simple continuous pattern. The number of throws per knot had a significant effect for knot security and tensile failure load. Surgeon experience had a significant effect on failure mode and tensile failure load.Conclusions: Suture type, number of throws per knot (knot size), suture pattern, and surgeon experience play an important role in knot security and should be considered when performing surgery.Keywords
This publication has 11 references indexed in Scilit:
- Evaluation of the histologic reactions to commonly used suture materials in the skin and musculature of ball pythons (Python regius)American Journal of Veterinary Research, 2011
- Minimum Number of Throws Needed for Knot SecurityJournal of Surgical Education, 2011
- In Vitro Comparison of Mechanical and Degradation Properties of Equivalent Absorbable Suture Materials from Two Different ManufacturersVeterinary Surgery, 2011
- Tensile Strength of a Surgeon's or a Square KnotJournal of Surgical Education, 2010
- In vitro Comparison of Secure Aberdeen and Square Knots with Plasma- and Fat-Coated PolydioxanoneVeterinary Surgery, 2010
- Knot Security in Simple Sliding Knots and Its Relationship to Rotator Cuff Repair: How Secure Must the Knot Be?Arthroscopy, 2000
- Mechanical Properties of Suture Materials In Vitro and after In Vivo Implantation in HorsesVeterinary Surgery, 1992
- Knot Security of Suture MaterialsVeterinary Surgery, 1989
- Tissue Reaction to Suture Material in the Feline Linea Alba A Retrospective, Prospective, and Histologic StudyVeterinary Surgery, 1987
- Considerations for Selection of Suture MaterialsVeterinary Surgery, 1978