Automated meal detection from continuous glucose monitor data through simulation and explanation
Open Access
- 27 September 2019
- journal article
- research article
- Published by Oxford University Press (OUP) in Journal of the American Medical Informatics Association
- Vol. 26 (12) , 1592-1599
Abstract
Background: Artificial pancreas systems aim to reduce the burden of type 1 diabetes by automating insulin dosing. These systems link a continuous glucose monitor (CGM) and insulin pump with a control algorithm, but require users to announce meals, without which the system can only react to the rise in blood glucose.Objective: We investigate whether CGM data can be used to automatically infer meals in daily life even in the presence of physical activity, which can raise or lower blood glucose.Materials and Methods: We propose a novel meal detection algorithm that combines simulations with CGM, insulin pump, and heart rate monitor data. When observed and predicted glucose differ, our algorithm uses simulations to test whether a meal may explain this difference. We evaluated our method on simulated data and real-world data from individuals with type 1 diabetes.Results: In simulated data, we detected meals earlier and with higher accuracy than was found in prior work (25.7 minutes, 1.2 g error; compared with 48.3 minutes, 17.2 g error). In real-world data, we discovered a larger number of plausible meals than was found in prior work (30 meals, 76.7% accepted; compared with 33 meals, 39.4% accepted).Discussion: Prior research attempted meal detection from CGM, but had delays and lower accuracy in real data or did not allow for physical activity. Our approach can be used to improve insulin dosing in an artificial pancreas and trigger reminders for missed meal boluses.Conclusions: We demonstrate that meal information can be robustly inferred from CGM and body-worn sensor data, even in challenging environments of daily life.Keywords
Funding Information
- National Institutes of Health
This publication has 32 references indexed in Scilit:
- Insulin adherence behaviours and barriers in the multinational Global Attitudes of Patients and Physicians in Insulin Therapy studyDiabetic Medicine, 2012
- A closed-loop artificial pancreas based on model predictive control: Human-friendly identification and automatic meal disturbance rejectionBiomedical Signal Processing and Control, 2009
- Detection of a Meal Using Continuous Glucose MonitoringDiabetes Care, 2008
- Menstrual Cycle Effects on Insulin Sensitivity in Women with Type 1 Diabetes: A Pilot StudyDiabetes Technology & Therapeutics, 2007
- Exercise in Type 1 Diabetes2005
- Daily stress and glycaemic control in Type 1 diabetes: individual differences in magnitude, direction, and timing of stress-reactivityDiabetes Research and Clinical Practice, 2004
- Cyclic Changes in Glycemia Assessed by Continuous Glucose Monitoring System During Multiple Complete Menstrual Cycles in Women with Type 1 DiabetesDiabetes Technology & Therapeutics, 2004
- Stress Hyperglycemia and Prognosis of Stroke in Nondiabetic and Diabetic PatientsStroke, 2001
- Toward Physiological Understanding of Glucose Tolerance: Minimal-Model ApproachDiabetes, 1989
- Smoothing and Differentiation of Data by Simplified Least Squares Procedures.Analytical Chemistry, 1964