Frictional resistance of orthodontic wires tied with 3 types of elastomeric ligatures
Open Access
- 14 October 2011
- journal article
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 25 (6) , 526-530
Abstract
The aims of this study were to determine and compare frictional resistance obtained by low-friction and conventional elastomeric ligatures in the presence of artificial saliva, and observe whether this variable changed after 21 days. Super Slick® low-friction elastomeric ligatures and conventional ligatures of the brands TP conventional® and Unitek® were placed on standard edgewise maxillary central incisor metal brackets, slot .022" × .028" tying rectangular orthodontic wires .018" × .025". Three experimental groups were arranged according to the type of ligature and a control group in which no wires were used. The friction values obtained between the bracket/wire/ligature set were measured using a Universal Test Machine at a speed of 20 mm/minute, at two experimental time intervals: T0 - immediately after specimen fabrication; and T1 - 21 days after fabrication and immersion in artificial saliva at 37 ºC. Conventional Unitek ligatures and the low-friction ligature (Super Slick) showed the lowest friction values at T0. After 21 days (T1), however, conventional Unitek ligatures presented the lowest value. All groups assessed from T0 to T1 showed a numerical reduction in friction values, suggesting that time, heat and humidity may cause elastic degradation, however this was not verified statistically (P > 0.05).Keywords
This publication has 25 references indexed in Scilit:
- Friction and resistance to sliding in orthodontics: A critical reviewAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2009
- A comparison of different ligation methods on frictionAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2006
- Resistance to sliding with 3 types of elastomeric modulesAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2005
- Evaluation of friction of stainless steel and esthetic self-ligating brackets in various bracket-archwire combinationsAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2003
- Force decay and deformation of orthodontic elastomeric ligaturesAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1997
- Frictional resistances in stainless steel bracket-wire combinations with effects of vertical defectionsAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1996
- Synthetic elastomeric chains: A literature reviewAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1994
- The influence of bracket design on moment production during axial rotationAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1993
- Ligature wires and elastomeric rings: two methods of ligation, and their association with microbial colonization of Streptococcus mutans and IactobacilliEuropean Journal of Orthodontics, 1991
- Evaluation of friction between edgewise stainless steel brackets and orthodontic wires of four alloysAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1990